STEP 6  Inspect the unit before inserting it into the sleeve. The fan and 
blower wheel should be manually rotated to insure that they turn 
freely. Be sure the electrical cord will be out of the way when 
inserting the unit into the sleeve.
 
NOTE:  For your safety, DO NOT plug the electrical cord into an 
electrical outlet until installation is complete.
STEP 7  If the unit checks out OK, it is ready to be placed into position on 
bottom rails of the cabinet and pushed into place.
 
NOTE:  Do all lifting of the unit by the bottom pan only and with 
assistance or help as necessary (see Figure A).
STEP 8  Install the white chassis seal gasket (item #6, page 6) and the 
gray window seal gasket (item #5). Carefully insert the white 
gasket (item #6) between the chassis and the cabinet starting at 
either bottom corner and go up the side, across the top and down 
the opposite side. Insert the gray gasket (item #5) between the 
window sashes as shown in Figure D. If chassis seal gasket is 
not installed, the operation of the unit will be negatively affected. 
Also, the operation noise and outside noise will be amplifi ed.
STEP 9  Hold the decorative front as shown in Figure E. Insert the two 
tabs of the Decorative Front Panel into the slots in the top of the 
cabinet and lower the bottom of the decorative front to the bottom 
of the cabinet. Route the electrical cord to the right or left side 
of the bottom of the cabinet as required by the location of the 
electrical wall outlet. Use the notches provided at the bottom of 
the Decorative Front Panel for routing the electrical cord out of 
the unit. Attach the decorative front to the cabinet with two (2) 
No. 8 x ½" Phillips head screws (item #2, page 6).
STEP 10  CIRCUIT PROTECTION - If the air conditioner is circuit protected by a 
fuse, use a "TIME DELAY" fuse or HACR type Circuit Breaker due to 
momentary high current demand when your air conditioner is started. 
Before operating your unit, verify the ampere rating of the time-delay 
fuse or circuit breaker which protects your unit. The ampere rating 
of the time-delay fuse or circuit breaker shall be 15 amps. Refer to 
Operation section for more detailed operating instructions.
Figure  D
TO PREVENT AIR LEAKS AROUND 
THE AIR CONDITIONER, INSERT 
THE WHITE FOAM GASKET (item 
# 6, page 6) BETWEEN THE AIR 
CONDITIONER AND THE CABINET.
CHASSIS SEAL
GASKET
GRAY FOAM 
GASKET
(see illustration, 
item #5 on page 6)
SCREW, #8 x ½" PHILLIPS HEAD
(See ilustration, item # 2, page 6) 
2 REQUIRED (1 EACH SIDE) 
TAB SLOTS
NOTCHES PROVIDED 
FOR ELECTRICAL 
CORD EXIT
TAB 
LOCATIONS
Figure  E
STEP 1  After removing the unit from shipping carton, remove tape holding 
decorative front in place. Lay front in a safe out-of-the-way place, 
then slide chassis out of cabinet (see Figure A, page 7).
STEP 2  Remove the shell channel from the top of the cabinet (see Figure 
B, page 7).
 
NOTE:  Not applicable to heat pump models sold without quick 
mounting cabinet.
STEP 3  LAYOUT - Cut and frame in an opening in the desired wall area 
using the illustration as a guide (see Figure F).
STEP 4  Place the cabinet in the framed opening.
 
NOTE:  Measure and shim void spaces between the side of 
cabinet and wood framing before securing to wall.
EXPANSION ANCHOR BOLT
MOLLY OR TOGGLE BOLT
STEP 5  Position the front edge to extend into the room 3/4" minimum at 
top of cabinet and 1" minimum at bottom (see Figure G).
STEP 6  Secure each side of the cabinet with No. 8 x ⅞" hex head screws 
(item #3, page 6) or nails through the holes in the sides.
 
NOTE: ALTERNATE FASTENERS WHICH MAY BE USED FOR 
SECURING THE UNIT CABINET TO A WALL, INCLUDING 
MASONRY WALLS, ARE NOT FURNISHED (AVAILABLE AT 
LOCAL HARDWARE STORES).
Thru-the-wall installations