How to change airflow direction
The DISCHARGE GRILLE is installed at the factory to provide 45˚ 
upward airfl ow into the room. (Direction 1 in Figure 5).  If a vertical 
airfl ow is desired (Direction 2), the direction can be changed by rotating 
the DISCHARGE GRILLE.  
Unplug the air conditioner.  
Remove the DISCHARGE GRILLE RETAINER attached with one 
screw in the right side of the grille.  
Remove the DISCHARGE GRILLE from the retaining slots near the 
CONTROLS, and rotate the grille as shown in Figure 5. 
Reinstall the DISCHARGE GRILLE by placing it in its retaining slots. 
Reattach the DIS CHARGE GRILLE RE TAIN ER with the retaining 
screw. The unit is now ready to operate.
How to cover inner weather panel holes
Two beige plugs are included in the plastic bag taped to the WallMaster 
chassis. These plugs may be used to cover the two holes left after 
removing the inner weather panel (see Figure 5).  The plugs must be 
attached before the DECORATIVE FRONT frame is installed.
Electrical requirements
IMPORTANT:  Before you begin the actual installation of your air 
conditioner, check local elec tri cal codes and the information below.
Your air conditioner must be connected to a power supply with the same 
AC voltage and hertz rating as marked on the nameplate located on 
the chassis. Only alternating current (AC) can be used. Consult pages 
3 and 7 for the correct type of receptacle for your model.
An overloaded circuit will invariably cause malfunction or failure of an 
air conditioner, therefore, it is extremely im por tant that the electrical 
power and the wiring is adequate. Consult your dealer or power 
company if in doubt.
CIRCUIT PROTECTION - Before installing or relocating your 
Friedrich Room Air Conditioner, check the amp rating of the circuit 
breaker or "TIME-DELAY" fuse. Refer to the nameplate located on 
the air conditioner chassis to de ter mine the correct fuse or circuit 
breaker am per age for your model.  The rating MUST NOT exceed 
the value stated on the nameplate.  If the air conditioner is connected 
to a circuit protected by a fuse, a "TIME-DELAY" fuse must be 
used due to the momentary high current demands when your air 
conditioner is started.