Friedrich KP05A10 KP06A10 ユーザーズマニュアル

ページ / 27
—3—
1. PREFACE 
This service manual provides various service information, including the mechanical and electrical parts, etc. 
This room air conditioner was manufactured and assembled under a strict quality control system. 
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 
1.1 FEATURES
•  DESIGNED FOR COOLING ONLY 
•  POWERFUL AND INCREDIBLE COOLING
•  TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
•  BUILT-IN ADJUSTABLE THERMOSTAT
•  WASHABLE ONE-TOUCH FILTER
•  COMPACT SIZE  
1.2 SPECIFICATIONS 
MODELS 
ITEMS 
COOLING CAPACITY (BTU/h)
5,100
5,700
POWER SUPPLY (Phase, V, Hz)
1ø, 115V, 60HZ
INPUT (W) 
470
530
OPERATING CURRENT (AMP.)
4.4
4.8
REFRIGERANT CONTROL
CAPILLARY TUBE 
REFRIGERANT CHARGE (R-22)
330g (11.6 oz)
365g (12.9 oz)
INSIDE FAN
TURBO FAN 
OUTSIDE FAN
PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE
2-WAY (RIGHT AND LEFT)
CHASSIS
TOP-DOWN
PROTECTOR 
TEMPERATURE CONTROL
THERMISTOR
FAN MOTOR
6 POLES, 21W
6 POLES, 27W
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
KP05A10
KP06A10