In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical 
breaker and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. 
Always be sure to turn off the electrical breaker to ensure that power is completely off.
TROUBLESHOOTING
WARNING
Before requesting service, perform the following checks:
Symptom
Problem
See Page
NORMAL 
FUNCTION
Doesn’t operate 
immediately:
● If the indoor unit is stopped and then immediately started again, the 
compressor will not operate for about 3 minutes, in order to prevent 
fuse blowouts.
● Whenever the electrical breaker is turned off then on again the pro-
tection circuit will operate for about 3 minutes, preventing unit opera-
tion during that period.
Noise is heard:
●  During operation or immediately after stopping the unit, the sound of 
water fl owing in the air conditioner’s piping may be heard. Also, noise 
may be particularly noticeable for about 2 to 3 minutes after starting 
operation (sound of refrigerant fl owing).
●  During operation, a slight squeaking sound may be heard. This is the 
result of minute expansion and contraction of the front panel due to 
temperature changes.
●  During Heating operation, a sizzling sound may be heard occasional. 
This sound is produced by the Automatic Defrosting operation.
23
Smells:
●  Some smell may be emitted from the indoor unit. This smell is the re-
sult of room smells (furniture, tobacco, etc.) which have been taken 
into the indoor unit.
Mist or steam is emitted:
● During Cooling or Dry operation, a thin mist may be seen emitted 
from the indoor unit. This results from the sudden Cooling of room air 
by the cool air emitted from the indoor unit, resulting in condensation 
and misting.
●  During Heating operation, the outdoor unit’s fan may stop, and steam 
may be seen rising from the unit. This is due to Automatic Defrosting 
operation.
23
Airfl ow is weak or stops:
●  When Heating operation is started, fan speed is temporarily very low, 
to allow internal parts to warm up.
● During Heating operation, if the room temperature rises above the 
temperature setting, the outdoor unit will stop, and the indoor unit will 
operate at very low fan speed. If you wish to warm the room further, 
set the temperature for a higher setting.
●  During Heating operation, the indoor unit will temporarily stop opera-
tion (Max.15 minutes) as the Automatic Defrosting mode operates. 
During Automatic Defrosting operation, the OPERATION Indicator 
Lamp will fl ash.
23
● During Dry mode, the indoor unit will operate at low speed; in order 
to adjust room humidity, the indoor unit’s fan may stop from time to 
time. Also, the fan may operate at very low speed when adjusting 
room humidity.
8
●  During SUPER QUIET operation, the fan will operate at very low speed.
7
● In the monitor of AUTO operation, the fan will operate at very low 
speed.
8
Water is produced from 
the outdoor unit:
● During Heating operation, water may be produced from the outdoor 
unit due to Automatic Defrosting operation.
23