All installations and services must be performed by qualified service personnel. 
 
 
Or in this case, 
 
                         _2.5 A.     = 0.25 A. (Anticipator Setting)  
                            10        
 
iv.  Adjust the position of the anticipator indicator to match the calculated 
ammeter setting. If a slightly longer cycle is desired, the pointer should 
be moved to a higher setting. Slightly shorter cycles can be achieved 
by moving to a lower setting. 
 
v.  Remove the meter jumper wire and reconnect the thermostat. Check 
the thermostat in the heating mode for proper operation. 
 
If a digital ammeter is used, read the current draw directly from meter. 
(Steps 1 through 3 are not required.) The meter reading is the correct 
anticipator setting. 
 
3.  Blower Motor Speed Selection 
 
: Turn off the electrical power to the unit, before attempting 
to change supply air blower speed wiring. 
 
The OPB comes from the factory with the proper cooling speed selected 
and the heat rise set to approximately 65
°F on low-fire. 
 
The heat rise is determined by the nozzle size and the switch selection on 
the control board located in the vestibule compartment. 
 
Switches 1, 2 & 3 of switch block SW1 (the six switch red block) are used 
to select the proper blower speed.  Please refer to the table below: 
1
2
3
LOW-
FIRE 
HIGH FIRE 
HEAT RISE
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
74
ON
ON
OFF
67
OFF
OFF
ON
64
ON
OFF
ON
73
OFF
ON
ON
67
ON
ON
ON
60
OPERATION IN THIS RANGE MAY CAUSE 
COMBUSTION GASES TO CONDENSE AND VOID 
THE WARRANTY 
SW1 POSITION
OPERATION IN THIS RANGE MAY FORCE THE 
SAFETY LIMIT TO OPERATE REDUCING 
PERFORMANCE
FACTORY 
SET
30