All installations and services must be performed by qualified service personnel. 
 
: Waterproof type connectors must be used when connecting electrical power 
and control wiring to the unit to prevent moisture from being drawn into the unit during 
operation. 
 
 
Refrigerant is under pressure.  Guard against refrigerant spraying into the 
face or on skin.  Always wear protective equipment, i.e. safety glasses or goggles and 
gloves when working with refrigerant. 
 
Do not under any circumstances heat the refrigerant cylinder with a torch or 
by any other means other than warm water.  Excessive pressures generated in this 
manner may weaken the refrigerant container and result in an explosion! 
 
: To avoid injury from moving parts, or electrical shock, shut off the power to 
the appliance before removing blower compartment door and servicing this appliance. 
 
: When servicing controls, label all wires prior to disconnecting. Reconnect any 
removed wires correctly. Wiring errors can cause improper and dangerous operation. 
Dangerous operation can result in injury or damage. 
 
: Do not use this appliance if any part has been under water. Immediately call 
a qualified service technician to inspect the furnace and to replace any part of the 
control system and any gas control that has been under water. 
 
: The area around the appliance, including the top of the unit, must be kept 
clear and free of combustible materials, gasoline, and other flammable vapors and 
liquids.  
 
: The appliance vent terminal may be hot. If the terminal is hot, allow it to cool 
before touching it.  
 
: Shut off unit and disconnect the power source before disassembling the unit.  
 
: Never operate the appliance without clean air filters in place. 
 
: This appliance requires air for combustion, ventilation, and cooling. Do not 
block or obstruct air openings in the unit and the air space around the perimeter of the 
unit. 
 
All local codes and ordinances take precedence with regard to selection and 
installation of oil storage tank and oil supply (and return) lines. In the absence of local 
codes, all tanks and lines must be selected and installed according to the instructions in 
this manual and the Standard for the Installation of Oil-Burning Equipment, NFPA 31-
1997, or the latest edition.  
 
Turn off power to furnace. Before the oil piping system is placed into 
service, it must have been leak tested by a qualified heating contractor.