How To Connect
IMPORTANT: Please read following electrical safety data carefully.
1.  Remove front panel. See Figure 22.
2.  Remove junction box.
• 
Remove junction box cover by removing three screws from 
front. Remove junction box by taking out top, rear and side 
screws. See Figure 24.
WARNING 
Electrical Shock and/or Unit
Operation and Damage Hazard
Failure to follow this warning could result in
personal injury or death and/or unit damage.
Follow the National Electrical Code (NEC)
or local codes and ordinances.
For personal safety, this unit MUST BE
properly grounded.
Protective devices (fuses or circuit breakers)
acceptable for unit installations are specified
on the nameplate of each unit.
Do not use an extension cord with this unit.
Aluminum wiring in the building may present
special problems - consult a qualified
electrician.
When unit is in STOP position, there is
still voltage to the electrical controls.
Disconnect power to unit before servicing by:
1. Removing power cord (if it has one) from
    wall receptacle.
2. Removing branch circuit fuses or turning
    circuit breakers off at panel.
FRP017
UNIT
CONNECTOR
JUNCTION BOX
JUNCTION BOX COVER
High
Med
Low
Fan
Cool
Heat
Fan Spee
d
Mode
Temperatur
e
Power
Figure 25 
Junction Box Location
Figure 26 
Power Connection
FRP018
ACCESSORY
POWER SUPPLY CORD
OR HARD WIRE
High
Med
Low
Fan
Cool
Heat
Fan Spe
ed
Mode
Temperatur
e
Power
3.  Connect accessory power supply cord or hard wire connector to 
unit connector. See Figure 26.
• 
Units must be installed using the appropriate power supply  
kit. See Table 2 --POWER CONNECTION CHART. These 
connections must be followed.
See Table 2 on page 14 for power cord accessory options and ratings.
4.  Reinstall junction box and cover.
• 
Use wire clamp to attach power cord to basepan. Secure 
with screws (included) See Figure 27.
• 
Replace junction box and cover with screws removed from 
Step 2. Tighten securely.
5.  Replace front panel. See Figure 24.
6.  Connect power to unit.
Figure 27 
Wire Clamp
FRP019
WIRE CLAMP
High
Med
Low
Fan
Cool
Heat
Fan Spee
d
Mode
Temperatu
re
Power