Fig. 2—Unit Base Dimensions, 50ZH024-030
UNIT
ELECTRICAL CHARACTERISTICS
UNIT WEIGHT
CENTER OF GRAVITY IN. (MM)
lb
kg
X
Y
Z
50ZH024
208/230-1-60
232
106
14.0 (356)
19.0 (483)
12.0 (305)
50ZH030
208/230-1-60,
208/230–3–60
254
116
14.0 (356)
19.0 (483)
12.0 (305)
C00156
REQUIRED CLEARANCE FOR OPERATION AND SERVICING
INCHES [mm]
CONDENSER 
.
 COIL ACCESS SIDE..............................................30.00 [762.0]  
POWER ENTRY SIDE....................................................................30.00 [762.0]
    (EXCEPT FOR NEC REQUIREMENTS)
UNIT TOP .......................................................................................48.00 [1219.2]
SIDE OPPOSITE DUCTS ..............................................................30.00 [762.0]
       LEGEND
NEC – National Electrical Code
NOTES:
1.  Clearances must be maintained to prevent recirculation of air from outdoor-
fan discharge, with the exception of the condenser coil (36.00 in [914.0 mm]. A
removable fence or barricade requires no clearance.
2. Dimensions are in inches. Dimensions in [ ] are in millimeters.
      
REQUIRED CLEARANCE TO COMBUSTIBLE MATL.
INCHES [mm]
TOP OF UNIT .........................................................................................0
DUCT SIDE OF UNIT.............................................................................0
SIDE OPPOSITE DUCTS ......................................................................0
BOTTOM OF UNIT .................................................................................0
NEC. REQUIRED CLEARANCES.
INCHES [mm]
BETWEEN UNITS, POWER ENTRY SIDE ....................................42.00 [1066.8]
UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE .36.00 [914.0]
UNIT AND BLOCK OR CONCRETE WALLS AND OTHER
GROUNDED SURFACES, POWER ENTRY SIDE.........................42.00 [1066.8]
3