Carrier 33ZCVAVTRM ユーザーズマニュアル

ページ / 52
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
PC 111
Catalog No. 533-355
Printed in U.S.A.
Form 33ZC-1SI
Pg 1
303
11-99
Replaces: New
Book 1
4
Tab
11a 13a
Installation, Start-Up and
Configuration Instructions
Part Numbers 33ZCFANTRM, 33ZCVAVTRM, 33ZCSECTRM
CONTENTS
Page
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2-29
General  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
Zone Controller Hardware . . . . . . . . . . . . . . . . . . . . . . . .  2
Field-Supplied Hardware . . . . . . . . . . . . . . . . . . . . . . . . .  2
• SPACE TEMPERATURE SENSOR
• PRIMARY AIR TEMPERATURE SENSOR
• SUPPLY AIR TEMPERATURE (SAT) SENSOR
• RELATIVE HUMIDITY SENSOR
• INDOOR AIR QUALITY (CO
2
) SENSOR
Mount Zone Controller  . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
• LOCATION
• MOUNTING
Connect the Power Transformer . . . . . . . . . . . . . . . . . .  7
Connect Airflow Pickups . . . . . . . . . . . . . . . . . . . . . . . . .  7
Install Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
• SPACE TEMPERATURE SENSOR INSTALLATION
• PRIMARY AIR TEMPERATURE SENSOR 
INSTALLATION
• SUPPLY AIR TEMPERATURE (SAT) SENSOR 
INSTALLATION
• INDOOR AIR QUALITY SENSOR INSTALLATION
• HUMIDITY SENSOR (WALL-MOUNTED) 
INSTALLATION
Remote Occupancy Contact. . . . . . . . . . . . . . . . . . . . . 26
Connect the Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26
Modulating Baseboard Hydronic Heating . . . . . . . .  26
Connect the CCN Communication Bus . . . . . . . . . . 26
• COMMUNICATION BUS WIRE SPECIFICATIONS
• CONNECTION TO THE COMMUNICATION BUS
START-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  29-31
Perform System Check-Out  . . . . . . . . . . . . . . . . . . . . .  29
Network Addressing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Initial Operation and Test. . . . . . . . . . . . . . . . . . . . . . . .  30
Airflow Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Fan and Heat Configuration and Test. . . . . . . . . . . .  30
CONFIGURATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31-50
Points Display Screen . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
Modify Controller Configuration. . . . . . . . . . . . . . . . .  32
• ALARM LIMIT CONFIGURATION SCREEN
• CONTROLLER IDENTIFICATION SCREEN
• HOLIDAY CONFIGURATION SCREENS
• LINKAGE COORDINATOR CONFIGURATION
SCREEN
• OCCUPANCY CONFIGURATION SCREEN
• SET POINT SCREEN
Service Configuration Selection Screen. . . . . . . . .  37
• AIRFLOW SERVICE CONFIGURATION SCREEN
• TERMINAL SERVICE CONFIGURATION SCREEN
• OPTIONS SERVICE CONFIGURATION SCREEN
• SECONDARY DAMPER SERVICE
CONFIGURATION SCREEN
Maintenance Table Menu Screen . . . . . . . . . . . . . . . .  43
• LINKAGE MAINTENANCE TABLE
• OCCUPANCY MAINTENANCE TABLE
• ZONE AIR BALANCE/COMMISSIONING TABLE
• ZONE MAINTENANCE TABLE
SAFETY CONSIDERATIONS
SAFETY NOTE
Air-handling equipment will provide safe and reliable
service when operated within design specifications. The
equipment should be operated and serviced only by
authorized personnel who have a thorough knowledge
of system operation, safety devices and emergency
procedures.
Good judgement should be used in applying any manu-
facturer’s instructions to avoid injury to personnel or dam-
age to equipment and property.
Disconnect all power to the unit before performing mainte-
nance or service. Unit may automatically start if power is
not disconnected. Electrical shock and personal injury
could result.
If it is necessary to remove and dispose of mercury contac-
tors in electric heat section, follow all local, state, and fed-
eral laws regarding disposal of equipment containing
hazardous materials.
Single Duct Air Terminal Zone Controller
VAV Fan Terminal Zone Controller
Secondary Terminal Zone Controller