Lochinvar EBN-SUB-05 プリント

ページ / 2
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN  37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
3/10—Printed in U.S.A.
Efficiency
+
® 
Boiler Dimensions & Specifications
Venting Options
AMP  DRAW  DATA
150,000 thru 300,000 Btu Models
FIRING
 CONTROLS
F-9
(Single Stage)
M-9
(Two Stage)
FAN
1.15
1.15
PUMP
AMPS
  100      150-300
   
    2.1             5.8
    2.1             5.8
VALVE/
CON TROLS
3.97
4.15
MAXIMUM 
TOTAL AMPS
@ 120 VAC
5.12
5.30
MODEL NO.
EB 150-200
EB 250-300
DIM “A”
9-1/8”
9-5/8”
DIM “B”
8-7/8”
9-3/8”
DIM “C”
7-1/8”
7-5/8”
DIM 
“D”
7-3/8”
7-3/4”
Horizontal Direct Vent Inlet and Outlet Cap
DIM 
“E”
4-3/8”
4-3/8”
   Conventional
   Efficiency+ DirectAire 
   Direct Vent Vertical 
   Direct Vent Horizontal 
   Outdoor
Efficiency+ Boiler 
 
   Dimensions & Spec i fi ca tions
 Input 
 
 
Heating 
Net
   Model 
Max 
AFUE  Capacity  I=B=R 
 
 
 
 
Gas 
Vent 
Shipping
  Number 
MBH 
MBH 
MBH 
Conn. 
Size 
Weight
EBN150 
150 
83.2 
129 
112 
19-3/4” 
16”     
  7-1/4” 
11-3/4” 
 3/4” 
5” 
245
EBN200 
200 
83.1 
170 
148 
23-3/4” 
20”     
  9-1/4” 
11-3/4” 
 3/4” 
5” 
265
EBN250 
250 
83.2 
218 
190 
27-1/2” 
23-3/4” 
11”     
11-3/4” 
 3/4” 
6” 
290
EBN300 
300 
84.0 
252 
219 
31-1/4” 
27-1/2” 
13”     
11-3/4” 
 3/4” 
6” 
310
Notes:  Change ‘N’ to ‘L’ to denote L.P. gas models 
Electrical Requirements: 120 VAC / 2 AMP   
Water connections are 1-1/2” NPT 
 
Net ratings based on piping and pick-up allowance of 1.15 
Performance data based on manufacturer test results.