Energy Tech Laboratories CL Series ユーザーズマニュアル

ページ / 52
6
TABLE :  BURNER SPECIFICATIONS
Beckett AFG
Boiler Model
Firing Rate 
GPH
Settings
Nozzle
 Pump 
Pressure
Head 
(Setting)
Air
Shutter
Air
Band
GPH x Angle Type
      
  
Shipped 
    1
  CL3-091
0.65
L1
8
0
0.55 x 70B (Delavan)
p Loose
140
       CL3-105
0.75
L1
6
0
0.65 x 45B (Hago)
p Loose
140
p CL3-140
1.00
L1
10
1
0.85 x 45B (Hago)
       Installed
140
       CL4-126
0.90
L1
7
0
0.75 x 45B (Delavan)
       Installed
140
       CL4-175
1.25
V1(0)
10
1
1.00 x 45B (Hago)
  Loose
175
 CL4-210
1.50
V1(0)
10
2
1.10 x 45B (Hago)
       Installed
175
       CL5-168
1.20
V1(2)
10
0
0.90 x 45B (Hago)
l Loose
175
l CL5-245
1.75
V1(3)
7
3
1.35 x 45B (Hago)
      Installed
175
      CL5-280
2.00
V1(4)
10
3
1.50 x 45B (Hago)
      Installed
175
Carlin Burner
Boiler Model
Firing Rate 
GPH
Burner 
Model
Settings
Nozzle

 Pump 
Pressure
Head 
Bar
Air
Band
GPH x Angle Type
    
   
Shipped
       CL3-091
0.65
EZ-1HP
0.50
0.55
0.55 x 70B (Delavan)
p Loose
150
       CL3-105
0.75
0.60/0.65
0.60
0.60 x 60ES (Hago)
p Loose
150
p CL3-140
1.00
0.85/1.00
0.75
0.85 x 60B (Hago)
       Installed
150
       CL4-126
0.90
0.75
0.75
0.75 x 60A (Delavan)
  Loose
150
       CL4-175
1.25
0.85/1.00 1.00-1.10
1.00 x 60A (Delavan)
  Loose
150
 CL4-210
1.50
1.10/1.25 1.25-1.35
1.25 x 60B (Hago)
       Installed
150
       CL5-168
1.20
0.85/1.00
0.90
1.00 x 60B (Hago)
       Installed
150
       CL5-245
1.75
EZ-2HP
1.50
1.75
1.50 x 60A (Delavan)
       Installed
150
1
  Beckett low firing rate baffle required on CL3-091 (0.65 GPH) application only; shipped loose with nozzle.  
2
  Nozzle(s) for alternate boiler model firing rate(s) are shipped loose in bag attached to the 
   burner designated by corresponding symbol, i.e. (
p) = CL3-140.

  Single stage fuel pump is standard, two stage fuel pump is optional.  Burner manufacturer has preset 
   single stage fuel pump to settings shown in table above.