Lopi Leyden Pellet Stove ユーザーズマニュアル

ページ / 42
3 6
Maintenance
Travis Industries
4061016
1 0 0 - 0 1 1 8 4
Yearly Maintenance (or every two tons) - continued
Clean the Exhaust Blower
The exhaust blower cover is held in place with 4 screws.
Remove the cover plate on the exhaust blower.  Clean the area inside the blower, removing all flyash.
     
Flow Switch Tube
Nipple (attached to exhaust channel)
Remove  the
side  cover.
Remove these 3 nuts to
expose  the  exhaust  blower.
Use  the  bottle  brush  to  disoldge  any
flyash  near  the  exahust  blower  and  in  the
horizontal  exhaust  channel.    Take  care
to  not  damage  the  impeller  on  the
exhaust  blower.
Check  the  nipple  and  flow  switch  tube.    Insert  a  pipe
cleaner  through  the  nipple  to  dislodge  any  flyash.
NOTE:  The  flow  switch  will  shut  off  the  auger  if  the
tube  becomes  clogged  or  dislodged.    Make  sure  it  is
cleaned  out  and  correctly  attached.