INSTALLATION
GENERAL REQUIREMENTS
CAUTION:
EQUIPMENT MUST BE INSTALLED BY A QUALIFIED
HEATING PERSON.
HEATING PERSON.
CAUTION:
ONLY “CLASS A” ALL-FUEL OR SOLID FUEL CHIM-
NEYS INTENDED FOR USE WITH YOUR WOOD-
CHUCK SHOULD BE USED.
NEYS INTENDED FOR USE WITH YOUR WOOD-
CHUCK SHOULD BE USED.
FIRST AND ABOVE ALL is safety for you and your
family.
family.
MUST USE: Class A Masonry or ULC listed, manufac-
tured Class A All Fuels Chimney.
RECOMMENDED SIZE: Rectangular 8"x12" or Round
8".
tured Class A All Fuels Chimney.
RECOMMENDED SIZE: Rectangular 8"x12" or Round
8".
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE. The Woodchuck is
to be used in conjunction with a listed gas or oil fired
furnace or as a central furnace.
SERVING ANOTHER APPLIANCE. The Woodchuck is
to be used in conjunction with a listed gas or oil fired
furnace or as a central furnace.
ELECTRICAL SUPPLY: 115 volts, 60HZ, 1 Phase,
less than 12 amps.
less than 12 amps.
Install system with 0.2 static pressure.
Flue setting .06 W.C. Max to .04 W.C. Min.
Flue setting .06 W.C. Max to .04 W.C. Min.
Wood or coal related fires are caused almost exclu-
sively by installation, operation or maintenance errors;
but not by unsafe equipment.
sively by installation, operation or maintenance errors;
but not by unsafe equipment.
IMPORTANT: Check with your local state and federal
codes on installation at your local fire department.
codes on installation at your local fire department.
PLACEMENT AND MINIMUM CLEAR-
ANCES
ANCES
CAUTION:
FURNACE MUST BE INSTALLED ON A NON-COM-
BUSTIBLE FLOOR OR 3/8" THICK FIREPROOF MILL-
BOARD OR EQUIVALENT.
BUSTIBLE FLOOR OR 3/8" THICK FIREPROOF MILL-
BOARD OR EQUIVALENT.
Locating your unit is very important for proper draft and
most efficient heating possible. See figure 7.
most efficient heating possible. See figure 7.
FIGURE 7
LOCATING THE WOODCHUCK