CHECKING GAS PRESSURE 
AND
 CONNECTING REMOTE RECEIVER 
MILLIVOLT CONTROL (FIGURE 10)
The valve regulator controls the burner pressure which should 
be checked at the pressure test point.
If outlet pressure is low, check inlet pressure against data plates 
or manual. 
Turn captured slotted screw counter clockwise 2 or 3 turns and 
then place tubing to pressure gauge over test point (Use test 
point “OUT” closest to control knob). After taking pressure 
reading, be sure and turn captured screw clockwise firmly to 
re-seal. Do not over torque. Check for gas leaks.
NOTE: Remove control panel to access gas valve 
and ignitor battery module. 
Figure 10 - Pressure Test Point Location
Milli-Volt Control 
Test Port “OUT”
CONNECTING REMOTE RECEIVER
  1.  Remove  cover  on  control  panel  to  show  opening  for 
remote receiver. See Figure 11. 
  2.  Cut cable to length (approximately 12") for placement in 
the fireplace. 
  3.  Strip back 
1
/
4
" of the insulation from free end of each 
wire. Do not cut off wire connector. 
  4.  Connect two .25 female connectors to the wires at free 
end of the cable.  
  5.  Insert the wire connector into the receiver. If remote does 
not have plug-in connector, strip back 
1
/
4
" of insulation. 
Insert wire into terminal and tighten screws. 
  6.  Connect the connectors to the two .25" male connectors 
located on the left side when facing the unit. See Figure 
11. Do not let the wire touch the grate or burners. 
  7.  Slide remote receiver in the opening of control panel. 
Use two screws provided to attach remote receiver to the 
control panel. See Figure 11. 
  8.  Replace Cover. See Figure 11. 
Figure 11 - Installing Remote Receiver 
Remote Receiver 
Cover  
NOTE: Do not place remote in combustion chamber. 
Connecting directly to an unregulated 
propane/L.P.G.  tank  can  cause  an 
explosion.
W
ARNING
   The heater gas inlet connection is 3/8" NPT at the valve. The 
inlet is located on left side of stove. Remove front control plate 
to better access the inlet. 
When tightening up the joint to the valve, hold the valve securely 
with a wrench to prevent movement.
Test all gas joints from the gas meter to the heater valve for 
leaks using a gas analyzer or soap and water solution after completing connection.  DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to HIGH.