       WARNINGS
The  blower  must  be  plugged  directly  into  a  properly 
grounded three-prong receptacle, 120 VAC, 60 Hz, single 
phase. Do not cut or remove the grounding prong from 
this plug.  Do not route power cord under or in front of 
appliance.
Installation must be in accordance with National Elec-
trical Code, ANSI/NFPA 70 - latest edition.  In Canada, 
the current CSA C22-1 Canadian Electrical Code - latest 
edition.
DANGER: Disconnect power before servicing blower.
BLOWER OPERATION
Figure 12 - Blower Wiring Schematic
Figure 11 - Blower Controls
Blower Operation
The  blower  can  be  operated  manually  or  automatically  (blower  will 
turn on when the insert is hot and turn off when the insert is cool).  
The rocker switch on the control panel allows you to select between 
manual operation or automatic operation as follows (see Figure 10): 
MANUAL OPERATION:  Turn rocker switch to the manual position (up) 
and adjust rheostat knob to the desired speed. The blower will have to 
be manually turned “OFF” by rotating the rheostat knob counterclock-
wise until it clicks.
AUTO  OPERATION:  Turn  rocker  switch  to  the  “AUTO”  position  and 
the rheostat to the ON position (rotate rheostat knob clockwise until it 
clicks). When the insert warms up, the blower will automatically turn 
on (adjust rheostat knob to the desired speed setting). When the insert 
cools down, the blower will automatically turn off.
Rheostat Operation -  The highest blower speed is obtained by turning 
the rheostat knob clockwise until it clicks “ON”, then rotate towards 
“HIGH” to increase blower speed.  Rotate the knob clockwise for a 
lower speed.  To turn off, continue to rotate the knob counterclockwise 
until it clicks “OFF.”
Blower Speed Control 
Knob (rheostat)
Manual / Auto
Rocker Switch
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
RED
RED
RED
YLW
BLK
WHT
GRN
NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
RED
RED
RED
YLW
BLK
WHT
GRN
NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION
Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on 
the temperature of the appliance.  Auto operation ensures there is suffi-
cient heat build-up to warm the air being moved by the blower before the 
blower is turned on.  Likewise, when the appliance cools off, the blower 
is turned off to prevent circulating cool air. Depending on the size and 
intensity of the fire it may be necessary to adjust the blower speed ac-
cordingly to ensure un-interrupted blower operation. For example a small 
fire may require a slower blower speed to keep the heat output by the 
blower consistent.  If the blower is operated in manual mode, it may be 
necessary to adjust the blower speed as the fire begins to burn down and 
the appliance is no longer hot enough to effectively heat the air moved 
by the blower.  If the air coming from the blower feels cool, one should 
either decrease the blower speed or stoke the fire to build up more heat.
NOTE: Turn blower off before opening the door to load the fuel.
ROOM AIR
BLOWER
SPEED
CONTROL/OFF
TWO POSITION
SWITCH
MANUAL/TEMPERATURE
AUTO-RESET
TEMPERATURE
SWITCH N/O
POWER CORD
RED
RED
RED
YLW
BLK
WHT
GRN
NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE
N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN
         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.