Heatiator ECO-ADV-WS22 ユーザーズマニュアル

ページ / 48
2
Heatilator • ECO-ADV-WS22 • 7057-128C • August 13, 2010
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
LOCATION:  Back of Appliance
Read this manual before installing or operating this fireplace.
Please retain this owner’s manual for future reference.
Congratulations!
Congratulations on selecting a Heatilator wood burning
appliance. The wood burning appliance you have selected
is designed to provide the utmost in safety, reliability and
efficiency.
As the owner of a new wood burning appliance, you’ll want
to read and carefully follow all of the instructions contained
in this owner’s manual. Pay special attention to all cautions
and warnings.
This owner’s manual should be retained for future refer-
ence. We suggest you keep it with your other important
documents and product manuals.
Your new wood burning appliance will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heatilator family of wood burning products!
NOTE:  Clearances may only be reduced by means 
approved by the regulatory authority having jurisdiction
SPÉCIFICATIONS DE LA VENTILATION:
MUR SIMPLE: De six (6 inches) (152mm) de diamètre le connecteur de conduit de 
minimum d'acier noir ou bleu de minimum de 24MSG, avec une cheminée bâtit en 
usine UL103HT* de Classe "A", adéquate pour usage avec les combustions solides, 
ou une cheminée de briques, avec espaces libres référés.
MUR  DOUBLE:  De  six  (6  inches)  (152mm)  de  diamètre,  le  connecteur  du  conduit 
d'air isolé pour mur double avec une cheminée bâtit en usine UL103HT* de Classe 
"A, ou une cheminée de briques, avec espaces libres alloués.
MAISON  MOBILE:    Utiliser  un  conduit  de  mur  double  par  Dura-Vent  DVL,  Selkirk 
Metalbestos  DS  ou  Security  DL.  Doit  être  équipé  d'un  arrêt  d'étincelle.  Utiliser  les 
espaces libres pour mur double comme mentionné ci-bas.
MINIMUM CLEARANCES TO COMBUSTIBLES  In Inches & (Millimeters) 
NOTE:  All "A" , "C" and "F" Dimensions are to inside diameter of the flue collar. 
LISTED ROOM HEATER, SOLID FUEL TYPE.   
ALSO FOR USE IN MOBILE HOMES.  (UM) 84 HUD .  
"For Use with Solid Wood Fuel Only"  
1445 N. Highway, Colville, WA 99114
www.heatilator.com
Install  and  use  only  in  accordance  with 
manufacturer's  installation  and  operating 
instructions.  Contact local building or fire officials 
about  restrictions  and  installation  inspections  in 
your  area.  Do  not  obstruct  the  space  beneath 
heater.
WARNING - For Mobile Homes:  Do not install in 
a sleeping room.  An outside combustion air inlet 
must be provided and unrestricted while unit is in 
use.    The  structural  integrity  of  the  mobile  home 
floor,  ceiling  and  walls  must  be  maintained.   The 
stove needs to be properly grounded to the frame 
of  the  mobile  home.    Components  required  for 
mobile  home  installation:    Outside  Air  Kit,  Part 
Number OAK-ACC.
Refer  to  manufacturer's  instructions  and  local 
codes  for  precautions  required  for  passing 
chimney through a combustible wall or ceiling and 
maximum offsets.
Inspect  and  clean  chimney  frequently  -  Under 
Certain Conditions of Use, Creosote Buildup May 
Occur Rapidly.
Do  not  connect  this  unit  to  a  chimney  serving 
another appliance.
Optional  Components:    Optional  Blower,  Part 
BK-ACC.
Electrical Rating:  115 VAC, 1.2 Amps, 60 Hz.
Route  power  cord  away  from  unit.    Do  not  route 
cord under or in front of appliance.
DANGER: Risk of electrical shock.  Disconnect 
power supply before servicing.
Replace  glass  only  with  5mm  ceramic  available 
from your dealer.
Do not use grate or elevate fire.  Build wood fire 
directly on hearth.
Do  not  overfire  -  if  heater  or  chimney  connector 
glows, you are overfiring.
CAUTION
:
 
U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to 
comply with July 1990 particulate emission standards.
2010  2011  2012
 
Jan.  Feb.  Mar.  Apr.  May  June July  Aug. Sept. Oct.  Nov.  Dec.
PREVENT HOUSE FIRES 
    
Report / Rapport:  3198460
Manufactured by:
HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS
 
SINGLE WALL PIPE 
10 (254)  8.25 (210)  21 (533)  11 (279) 
3.5 (89)  12.5 (318)  49 (1245) 
*
DOUBLE WALL PIPE 
9 (229) 
7 (178)  19.5 (495)  9 (229) 
3 (76) 
12 (305)  49 (1245)  10 (254)
SINGLE WALL PIPE     
  9.25 (235)  7.5 (191)  18 (457) 
8 (203) 
3.5 (89)  12.5 (318)  49 (1245) 
*
 
DOUBLE WALL PIPE 
9.25 (235)  7.5 (191)  18 (457) 
8 (203) 
3 (76) 
12 (305)  49 (1245)  10 (254)
VENT SPECIFICATIONS:
SINGLE  WALL:  Six  inch  (6  inches)  (152mm)  diameter,  minimum  24  MSG  black  or 
blued  steel  connector  pipe,  with  a  listed  factory-built  UL103HT*  Class  "A"  chimney, 
suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.
DOUBLE  WALL:  Six  inch  (6  inches)  (152mm)  diameter,  listed  double  wall  air 
insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or  a 
masonry chimney and the referenced clearances
*In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree 
Factory-built chimneys.
MOBILE HOME:  Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or 
Security  DL  double  wall  connector  pipe.  Must  be  equipped  with  a  spark  arrestor.  
Apply double wall clearances below when installing unit.
SERIAL NO. / NUMÉRO DE SÉRIE
WS22 WOOD STOVE
  
7057-125
CHAUD LORS DE L'OPÉRATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VÊTEMENTS LOIN DE L'ESPACE DÉSIGNÉ DE L'INSTALLATION. LE CONTACT PEUT CAUSER
DES BRÛLURES À LA PEAU. GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L'ESPACE DÉSIGNÉ DE L'APPAREIL. VOIR L'ÉTIQUETTE ET LES INSTRUCTIONS.
ATTENTION
:
APPAREIL DE CHAUFFAGE DE PIÈCE, DE TYPE DE 
COMBUSTIBLE SOLIDE, POUR USAGE DANS LES 
MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage 
Avec Bois Solide Seulement" 
Installez  et  utilisez  en  accord  avec  les  instructions 
d'installation et d'opération du fabricant. Contactez le bureau 
de la construction ou le bureau des incendies au sujet des 
restrictions  et  des  inspections  d'installation  dans  votre 
voisinage. Ne pas obstruez l'espace en dessous de l'appareil.
AVIS - Pour Les Maisons Mobiles:  Ne pas installer dans une 
chambre à coucher. Un tuyau extérieur de combustion d'air 
doit être installé et ne doit pas être obstrué lorsque l'appareil 
est en usage. La structure intégrale du plancher, du plafond et 
des  murs  de  la  maison  mobile  doit  être  maintenue  intacte. 
L'appareil  de  chauffage  doit  être  fixé  à  la  charpente  de  la 
maison mobile. Les composants requis pour l'installation des 
maisons  mobiles: Assemblage  d'air  extérieur,  Numéro  de 
Pièce OAK-ACC.
Référez  vous  aux  instructions  du  fabricant  et  des  codes 
locaux  pour  les  précautions  requises  pour  passer  une 
cheminée à travers un mur ou un plafond combustibles, et les 
compensations maximums.
Inspectez  et  nettoyez  la  cheminée  fréquemment.  Sous 
certaines  conditions,  il  se  peut  que  la  créosote  s'accumule 
rapidement.
Ne  pas  connecter  cet  appareil  à  une  cheminée  servant  un 
autre appareil.
Composants  Optionnels:  Ventilateur  Optionnel,  Pièce 
BK-ACC.
Puissance Électrique: 115 VAC, 1.2 Amps, 60 Hz.
Éloignez le fil électrique de l'appareil. Ne pas faire passer le fil 
électrique au dessus ou en dessous de l'appareil.
DANGER: Il y a risque de décharge électrique.  Déconnectez 
le fil électrique de la prise de contact avant le service.
Remplacez la vitre seulement avec une vitre céramique de 5 
mm disponible chez votre fournisseur.
N'élevez pas le feu. Bâtissez le feu de bois directement sur 
l'âtre.
Ne pas surchauffer. Si l'appareil de chauffage ou le tuyau de 
PRÉVENTION DES FEUX DE MAISON 
ESPACES LIBRES MINIMUM DES MATÉRIAUX COMBUSTIBLES En Pouces & 
(millimètres) 
NOTE:  Toutes les dimensions "A", "C", et "F" sont à partir du diamètre intérieur de 
l'entrée du conduit. 
BACKWALL/SIDEWALL
MUR ARRIÈRE/MUR DE CÔTÉ 
CORNER INSTALLATION
INSTALLATION DU COIN 
CONDUIT DU MUR SIMPLE
CONDUIT DU MUR SIMPLE
C
ONDUIT DU MUR DOUBLE
CONDUIT DU MUR DOUBLE
INSTALLATION: FULL VERTICAL / ENTIÈREMENT VERTICALE 
 
INSTALLATION: HORIZONTAL WITH MINIMUM 2 FT VERTICAL OFF STOVE TOP
INSTALLATION: HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POÊLE
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER L'ÉTIQUETTE
Made in U.S.A./Fait Aux États-Unis
*Au Canada doit conformer a CAN/ULC-S629-M87 la norme pour 650 degré C cheminée 
bâtit en usine. 
Fabriqué par:
007017
TESTED TO:/ TESTÉ À:
   UL 1482,  ULC S627
-
00. 
A
B
C
D
INSTALLATION:  90
ELBOW OFF TOP OF STOVE THROUGH BACKWALL
INSTALLATION:  90
DU COURBURE AU DESSUS DE HAUT DU POÊLE A TRAVERS LE MUR ARRIERE
Test Lab and 
Report Number
Model Name
Serial Number
Manufacturer Date
SAMPLE