FINAL CHECK
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi ring 
correctly. This includes:
1)  Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) after 15 
minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15 min. to stabilize.
3)  Check for proper draft.
SAFETY LATCH
Secure door in the closed position using the door 
securing bracket and the screw provided.
DOOR HANDLE
Attach spring handle by rotating counter clock-
wise onto rod.  Ensure that the spring fi ts into 
the entire length of the rod.  
Note:  Door securing bracket is there for 
safety.
Note:  The door must be kept closed at all 
times, except during maintenance. 
The unit must never be operated 
without the glass in the door, or with 
the door open.
REMOTE CONTROL 
INSTALLATION
Use the Regency
®
 Remote Control Kit approved 
for this unit. Use of other systems may void 
your warranty.
The remote control kit comes with a hand held 
transmitter, a receiver and a wall mounting 
plate.
1)  Choose a convenient location on the wall 
to install the receiver (protection from 
extreme heat is very important)
. Run 
wiresfrom the fi replace to that location. Use 
the Thermostat Wire Table.
2)  Connect the two wires to the gas valve. See 
diagram below.
CAUTION 
Do not wire the millivolt remote
control wires to the 120V AC 
wires.
3)  Install 3 AAA alkaline batteries in transmitter 
and 4 AA alkaline batteries in  the receiver. 
Install the receiver and its cover in the wall. 
Switch the  remote receiver to "remote" 
mode. The remote control is now ready for 
operation.
REMOTE WALL 
SWITCH
1)  Run the wire through the opening in the 
rear of the unit. Be careful not to damage 
any wires.
Note:  We recommend a maximum of 15' 
of wire but if you wish to go with a 
longer run use the Thermostat Wire 
Table.
2)  Connect the wire to the wall switch and 
install into receptacle box.
 CAUTION 
Do not wire the millivolt wall 
switch for gas appliance to the 
120V AC wires
WALL THERMOSTAT 
INSTALLATION
Regency
®
 offers an optional programmable 
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or 
UL approved may be used.
Connect the wires as per the wiring diagram. 
Use the Thermostat Wire Table to determine the 
maximum wire length.
CAUTION 
Do not wire the millivolt wall ther-
mostat wires to the 120V AC wires
Note: Preferable if the thermostat is installed 
on an interior wall.
Thermostat Wire Table
CAUTION: Any alteration to the product that 
causes sooting or carboning that results in 
damage to the unit is not the responsibility of 
the manufacturer and will not be covered by 
the warranty.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length 
(Two-Wire) When Using Wall 
Thermostat (CP-2 System)
Wire Size                       Max. Length
INSTALLATION