 F39 Room Sealed Freestanding Gas Stove
INSTALLATION
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained 
to customer
.
This includes:
1)
  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
CLEARANCES TO 
COMBUSTIBLES
The clearances listed are MINIMUM distances. 
Measure the clearance to both the appliance 
and the chimney connector. The farthest 
distance is correct if the two clearances do 
not coincide.
 
For example, if the appliance is set as indicated 
in one of the fi gures but the connector is too 
close, move the stove until the correct clearance 
to the connector is obtained.  
This appliance may be installed only with the 
clearances as shown in the situations pictured. 
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances.
This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting  or vinyl when 
the bottom pedestal cover plate (provided with 
unit) is installed.
Use the minimum clearances shown in the 
diagrams below:
F39-NG & F39-LPG Clearances
A  Side Wall to Unit 
190 mm
B Back Wall to Unit 
150 mm
E  Side Wall to Unit 
50 mm
F39-NG & F39-LPG Reference Dimensions
C  Back Wall to Flue Centerline 11" / 280 mm
D  Side Wall to Flue Centerline  521 mm
F  Side Wall to Flue Centerline   280 mm
10) Be aware of electrical wiring locations in 
walls and ceilings when cutting holes for 
termination.
11) Under no circumstances should this ap-
pliance be modifi ed. Parts that have to be 
removed for servicing should be replaced 
prior to operating this appliance.
12) Installation and any repairs to this appliance 
should be done by an authorised service 
person. An authorised service person should 
be called to inspect this appliance annually. 
Make it a practice to have all of your gas 
appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid 
fuels (wood, paper, cardboard, coal, etc.) 
be used in this appliance.
15) The appliance area must be kept clear and 
free of combustible materials, (gases and 
other fl ammable vapours and liquids).
INSTALLATION 
CHECKLIST
1)  Check Clearances to Combustibles. Refer to 
the "Clearance to Combustibles" section.
2)  Install Louvers. Refer to "Louver Installation" 
section. 
3)  Install fl ueing. Refer to the "Flueing" sec-
tion.
4)  Make gas connections. Refer to the "Gas 
Connection" section. Test the pilot. Must 
be as per diagram in the "Pilot Adjustment" 
section. 
5)  If necessary, convert NG to LPG. Refer to 
the "Conversion from NG to LPG" section.
6)  Test Gas Pressure. Refer to the "Gas Pipe 
Pressure Testing" section.
7)  Install log set. Refer to the "Log Set Instal-
lation" section
8)  Install Front Door. Refer to the "Front Door 
Installation" section.
9)  Install Optional Features. Refer to the 
following sections where applicable: 
 a. 
Optional 
Wall 
Thermostat
 
b. Optional Remote Control
10) Final check. Refer to the "Final Check" 
section.
Minimum ceiling 
height is  914 mm 
from top of unit.
LOCATING  YOUR  
REGENCY
®
 GAS STOVE
 
When selecting a location for your stove, ensure 
that the clearances listed above are met as well 
as ensuring that there is adequate accessibility 
for servicing and proper operation.
A) Cross Corner 
B) Room Divider
C) Island  
D) Flat on Wall
E)  Flat on Wall Corner
F) Flush with Wall/ Alcove