Regency F38-LPG2 ユーザーズマニュアル

ページ / 23
Regency F38-2 Freestanding Gas Heater
19
4)  Remove the two outside frame pieces by 
removing two screws per side.  See diagram 
below.
REMOVING VALVE
If your valve requires maintenance or replace-
ment, follow these instructions:
NOTE:   
Always shut off the gas supply  
  before removing the valve.
1)  Open front pedestal door and unhook chain. 
You may want to put a soft cloth on the base 
of the unit so that when the pedestal door 
is open it doesn't scratch the paint.  See 
diagram below.
2)  Undo the six screws holding the control 
panel in place.
3)  Disconnect all wires from the back of the 
panel and then remove panel.  You should 
lay the panel on a soft cloth so it doesn't get 
marked up.  See diagram below.
5)  Carefully remove the logs and lava rock.
6)  At this point you should disconnect the gas 
at the valve. 
7)  Remove the burner by removing the two
 
1/4" hex head screws. See diagram be-
low. 
9)  Carefully lift the burner tray assembly out.
Note: Use a magnetic type screwdriver.
8)  Remove eight 1/4" hex head screws holding 
the burner tray assembly in place.
10) To replace the burner tray assembly, simply 
reverse these instructions.  
MAINTENANCE