Regency FG39-LPG ユーザーズマニュアル

ページ / 36
Regency FG39 FireGenie Freestanding Gas Stove
21
INSTALLATION
Diagram  1
FRONT  DOOR
INSTALLATION
(packaged separately)
1) Open the two side panels.
2) Slide  the  door  onto  the  two  hinge  pins
making  sure  the  two  pieces  are  flush  to-
gether.  See diagram 1.
4) The latches should already be at the proper
setting.  If they are too hard or too easy to
close,  you  may  want  to  adjust  them  by
loosening the latch catch.  See diagram 3.
Diagram  2
Diagram  3
5) Remove the blue plastic protective coating
from the glass.
6) Test the seal around the door by placing a
piece  of  paper  between  the  unit  and  the
door, close the door and try to pull the paper
out. If it slips out easily, then the door is not
properly sealed. Tighten or loosen the latch.
See diagram 3.
Note: The  door  latch  may  require  ad-
justment  as  the  door  gasket  ma-
terial compresses after a few fires
and after glass replacement. Turn
the  latch  catch  inward  or  out-
ward  to  loosen  or  tighten.
3) Close  the  door.  The  latch  plate  must  be
centered  around  the  alignment  pin.    See
diagram 2.  If the latch plate interferes with
the  corner  of  the  stove  you  may  want  to
angle the plate slightly so the door closes
easier.
OPTIONAL
REMOTE  CONTROL
Use the Regency Remote Control Kit  approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter and a wall mounting plate.
1) Choose a convenient location to mount the
hand held transmitter, protection from ex-
treme heat is very important.
The remote can also be used as a wall thermo-
stat.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly.  This  includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) at 15
minutes.
2) If  required,  adjusting  the  primary  air  to
ensure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
3) Check  for  proper  draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of the
manufacturer.