Regency FG39-LPG ユーザーズマニュアル

ページ / 36
Regency FG39 FireGenie Freestanding Gas Stove
29
MAINTENANCE
4) Remove the two outside frame pieces by
removing  two  screws  per  side.    See  dia-
gram  below.
REMOVING  VALVE  TRAY
If your valve requires maintenance or replace-
ment,  follow  these  instructions:
NOTE: Always  shut  off  the  gas  and  dis-
connect  the  power  supply  before
removing  the  valve.
1) Open the front door and carefully remove
the logs and lava rock.
2) Remove the burner by removing the two
1/4" hex head screws. See diagram below.
3) Open the front pedestal door and unhook
chain. You may want to put a soft cloth on
the  base  of  the  unit  so  that  when  the
pedestal door is open it doesn't scratch the
paint.  See diagram below.
5) Remove  the  front  plate  by  undoing  the  6
screws.
6) Disconnect  the  manual  switch  cable  and
reset  cables.
7) Disconnect the gas pipe line at the valve.
8) Remove the pedestal back cover by remov-
ing the 4 Philips screws.
9) Disconnect the 5 pin molex connector.
10) Disconnect  the  ground  wires.
11) Remove  the  20  x  1/4"  hex  head  screws
holding the burner tray assembly in place.
12) Carefully lift the burner tray assembly out.
13) To replace the burner tray assembly,
reverse  these  instructions.
Reset  Cables
Ground
Wire
5 Pin
Molex  Connector
Manual  Switch
Cable