INSTALLATION
2) If  required,  adjusting  the  primary  air  to
ensure that the flame does not carbon. First
allow  the  unit  to  burn  for  15-20  min.  to
stabilize.
CAUTION:  Any  alteration  to  the  product
that  causes  sooting  or  carboning  that
results  in  damage  is  not  the  responsibil-
ity  of  the  manufacturer.
CLEARANCES  TO
COMBUSTIBLES
The clearances listed are MINIMUM distances.
Measure the clearance to both the appliance
and  the  chimney  connector.  The  farthest
distance  is  correct  if  the  two  clearances
do  not  coincide.
For example, if the appliance is set as indicated
in one of the figures but the connector is too
close, move the stove until the correct clear-
ance to the connector is obtained.
This appliance may be installed only with the
clearances  as  shown  in  the  situations  pic-
tured.  Do  not  combine  clearances  from
one  type  of  installation  with  another  in
order  to  achieve  closer  clearances.
This unit can be installed on a solid combustible
surface like a wood floor. This unit can also be
installed directly on carpeting  or vinyl when the
bottom  pedestal  cover  plate  (provided  with
unit) is installed.
Use  the  minimum  clearances  shown  in  the
diagrams  below:
FG39-NG & FG39-LPG Clearances
A Side Wall to Unit
190 mm
B Back Wall to Unit
150 mm
E Side Wall to Unit
50 mm
10) Be  aware  of  electrical  wiring  locations  in
walls  and  ceilings  when  cutting  holes  for
termination.
11) Under no circumstances should this appli-
ance  be  modified.  Parts  that  have  to  be
removed for servicing should be replaced
prior to operating this appliance.
12) Installation and any repairs to this appliance
should  be  done  by  an  authorised  service
person.  An  authorised  service  person
should be called to inspect this appliance
annually. Make it a practice to have all of
your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels  (wood,  paper,  cardboard,  coal,  etc.)
be used in this appliance.
15) The appliance area must be kept clear and
free of combustible materials, (gases and
other flammable vapours and liquids).
INSTALLATION
CHECKLIST
1) Check Clearances to Combustibles (page
6),    location  of  unit  (page  6)  and  fluing
requirements (pages 8 to 10).
2) Install Louvers, page 7.
3) Install fluing, either with the DV Stove Hor-
izontal Flue Kit (page 10) or the Dura-Flue
Termination kits (page 12). Set Flue Restric-
tors, page 9.
4) Make gas connections, page 16. Test the
pilot. Must be as per diagram.
5) If necessary, convert to LPG (page 17) or
convert to lower Btu rating (page 19).
6) Test Gas Pressure, page 16.
7) Install log set, see page 19.
8) Install Front Door Front, page 21.
9) Install optional Remote Control, page 21.
10) Final check, page 21.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly  and  operation  fully  explained  to
customer.
This  includes:
1) Clocking the appliance to ensure the correct
firing rate (rate noted on label) after burning
appliance for 15 minutes.
FG39-NG & FG39-LPG
Reference  Dimensions
C Back Wall to Flue Centerline 11" / 280 mm
D Side Wall to Flue Centerline 521 mm
F Side Wall to Flue Centerline  280 mm
Minimum  ceiling
height  is    914  mm
from top of unit.
LOCATING  YOUR
REGENCY  GAS  STOVE
When  selecting  a  location  for  your  stove,
ensure  that  the  clearances  listed  above  are
met as well as ensuring that there is adequate
accessibility  for  servicing  and  proper  opera-
tion.
A) Cross  Corner
B) Room Divider
C) Island
D) Flat on Wall
E) Flat on Wall Corner
F) Flush with Wall/ Alcove
For Flue Termination requirements, see page 8.
COMBUSTION  AND
VENTILATION AIR
The combustion air from this appliance is drawn
from outside the building through the outer flue.
Extra  provision  for  combustion  air  inside
the  room  is  not  required.
12’ (4m)
A
C
D
E
F
B
12’ (4m)
Max.
Max.