Regency F39-NG ユーザーズマニュアル

ページ / 31
Regency
®
 F39 Room Sealed Freestanding Gas Stove
15
GAS CONNECTION
The gas connection is a 3/8" NPT 90
o
 elbow. 
The gas line can be rigid pipe or to make in-
stallation easier, use a listed fl exible connector 
and/or copper tubing if allowed by local codes. 
Since some municipalities have additional 
local codes it is always best to consult with 
your local authorities and the CAN/CGA B149 
installation codes.
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so 
that gas lines can be easily disconnected for 
burner and/or valve servicing. Flare nuts for 
copper lines and fl ex connectors are  usually 
considered to meet this requirement.
Important: Always check for gas leaks with a 
soap and water solution or gas leak detector. 
Do not use open fl ame for leak testing.
Note:  Prior to any pressure testing of 
the gas supply piping system that 
exceeds test pressures of 3.45 kPa, 
this appliance must be disconnected 
from the piping system.  If test pres-
sures equal to or less than 3.45 kPa 
are used then this appliance must be 
isolated from the piping system by 
closing its individual manual shut-off 
valve during the testing.
GAS PIPE PRESSURE 
TESTING
The appliance must be isolated from the gas sup-
ply piping system by closing its individual manual 
shut-off valve during any pressure testing of the 
gas supply piping system at test pressures equal 
to or less than 3.45 kPa.  Disconnect piping from 
valve at pressures over 3.45 kPa.
The manifold pressure is controlled by a regu-
lator built into the gas control, and should be 
checked at the pressure test point.
INSTALLATION
Offset Chart
Diagram 13
sions, in the same manner as shown in 
diagram 10. 
b)  Any occupied areas above the fi rst fl oor, 
including closets and storage spaces, 
through which the vertical fl ue passes, must 
be enclosed. 
CATHEDRAL CEILINGS
Round Support (RDS) &
Square Support (SQS)
If your home has a cathedral ceiling (no attic 
space between the ceiling and the roof), install 
the chimney and support as follows.
    Slope 
"X"
0/12 - 
2/12 
4"
2/12 - 
7/12 
5-1/2"
7/12 - 
12/12  6-3/4"
12/12 - 24/12 
7-1/2"
24/12+  
12-1/2"
1)  Situate the chimney in a convenient loca-
tion as near as possible to the appliance 
outlet.  Cut and frame a hole in the roof for 
the support. The sides of this hole must be 
vertical with 1 1/4" clearance.
2)  Place the support in the opening. Lower it 
to the correct height as determined by the 
table and diagram below.
 
Using a level, make sure the support is 
vertical.  If the support extends above the 
roof, cut it fl ush with the top of the roof.  
Nail the support to the frame opening using 
(8) 3" spiral nails or #8 x 1-1/2" screws.
Note:  If you are using a 6" square support 
you may fi nd it diffi cult to screw it 
in place because it is fairly small 
inside.
 
Simpson Dura-Flue has provided angle 
brackets with this support which can be 
screwed to the outside of the support 
box and nailed to surrounding framing as 
required.  Use a minimum of four #8 x 1/2" 
screws per bracket.  In some cases these 
brackets may need to be trimmed (e.g.: 
to fi t under a fl ashing).  Place the Finish 
Collar around the support and fasten it to 
the ceiling using the screws provided.
3)  Use appropriate roof fl ashing.  Place the 
fl ashing under the upper shingles and on 
top of the lower shingles approximately 
half of the fl ashing should be under the 
shingles.  
4)  Assemble the desired lengths of Black Pipe 
and Elbows necessary to reach from the 
appliance adaptor up through the support 
box and fl ashing to proper height as per 
Dia. 12, local codes or page 9.  Ensure 
that all pipe and elbow connections are in 
their fully twist lock position.
5)  Ensure fl ue is vertical and secure fl ashing 
to the roof  with roofi ng nails.  Slide the 
storm collar over the pipe section and seal 
with a mastic.
6)  Twist lock the fl ue cap on to the last sec-
tion.
Support Extensions - Round 
(RDSE) or Square (SQSE)
Steep pitched cathedral ceilings may require 
the use of a support extension. This piece fi ts 
down inside the support and can be adjusted to 
increase the support's length by up to 22". The 
extension is attached to the support using the 
eight metal screws provided.  Be sure there is 
at least a 2 inch overlap where the extension 
joins the support.