INSTALLATION
FACTORY 
BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the 
ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. 
Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other 
obstructions for safety and proper draft operation.
MASONRY 
CHIMNEY
Ensure that a masonry chimney meets the mini-
mum standards of the National Fire Protection 
Association (NFPA) by having it inspected by 
a professional. Make sure there are no cracks, 
loose mortar or other signs of deterioration and 
blockage.  Have  the  chimney  cleaned  before 
the  stove  is  installed  and  operated.  When 
connecting  the  stove  through  a  combustible 
wall  to  a  masonry  chimney,  special  methods 
are needed.
MASONRY 
FIREPLACE
There are listed kits available to connect a stove 
to a masonry fireplace. The kit is an adapter 
that is installed at the location of the fireplace 
damper. The existing damper may have to be 
removed to allow installation.