9)  During  the  first  few  days  it  may  be  more 
difficult to start the fire. As you dry out your 
firebrick and your masonry flue, your draft 
will increase.
10) For those units installed at higher elevations 
or  into  sub-standard  masonry  fireplaces, 
drafting  problems  may  occur.  Consult  an 
experienced dealer or mason on methods 
of increasing your draft.
11) Some cracking and popping noises may be 
experienced during the heating up process. 
These noises will be minimal when your unit 
reaches temperature.
12) Before opening your door to reload, open 
draft fully for approximately 10 to 15 seconds 
until fire has been re-established. This will 
minimize any smoking.
13) All fuel burning appliances consume oxygen 
during operation.  It is important that you 
supply  a  source  of  fresh  air  to  your  unit 
while burning. A slightly opened window is 
sufficient for the purpose.  If you also have 
a fireplace in your home, a downdraft may 
be created by your Regency Stove causing 
a draft down your chimney. If this occurs, 
slightly open a window near your unit.
CAUTION:  If the body of your unit, 
flue baffle or any part of the chim-
ney connector starts to glow, you 
are over firing.  Stop loading fuel 
immediately and close the draft con-
trol until the glow has completely 
subsided.
14) Green or wet wood is not recommended for 
your unit.  If you must add wet or green fuel, 
open the draft control fully until all moisture 
has  been  dispersed  by  the  intense  fire.  
Once all moisture has been removed, the 
draft control may be adjusted to maintain 
the fire.
15) If you have been burning your stove on a low 
draft, use caution when opening the door.  
After opening the damper, open the door 
a crack, and allow the fire to adjust before 
fully opening the door.
16) The controls of your unit or the air supply 
passages should not be altered to increase 
firing for any reason.
17) If you burn the unit too slowly or at too low 
a setting your unit will not be operating as 
efficiently as it can.  An easy rule of thumb 
says that if your glass is clean, then your flue 
is clean and your exhaust is clean.  Burn the 
stove hot enough to keep your glass clean 
and you won't need to clean your flue as 
often.
4)  After about 45 minutes, when your wood 
has begun to burn strongly, adjust your draft 
control down to keep the fire at a moderate 
level.
 
WARNING:  Never build a roaring fire 
in a cold stove.  Always warm your 
stove up slowly!
5)  Once a bed of coals has been established 
on the firebrick hearth, you may adjust the 
draft control to a low setting to operate the 
unit at its most efficient mode.
6)  During the first few fires, keep the combus-
tion rate at a moderate level and avoid a 
large fire. Only after 5 or 6 such fires can you 
operate the stove at its maximum setting, and 
only after the metal has been warmed.
7)  For the first few days, the stove will give off an 
odour from the paint. This is to be expected 
as the high temperature paint becomes sea-
soned. Windows and/or doors should be left 
open to provide adequate ventilation while 
this temporary condition exists. Burning the 
stove at a very high temperature the first few 
times may damage the paint. Burn fires at 
a moderate level the first few days.
8)  Do not place anything on the stove top dur-
ing the curing process. This may result in 
damage to your paint finish.
Pull - Open                Push - Closed
WARNING:  To build a fire in ignorance 
or  to  disregard  the  information  con-
tained in this section can cause serious 
permanent damage to the unit and void 
your warranty!!
DRAFT CONTROL
Both the primary and air wash drafts are control-
led by the control rod located on the left side 
of the unit (when facing the unit). To increase 
your draft - pull open, and to decrease - push 
closed.  All units have a secondary draft system 
that  continually  allows  combustion  air  to  the 
induction  ports  at  the  top  of  the  firebox,  just 
below the flue baffle.  
Important:  If you are using room air for combus-
tion, make sure that the back cover plate at the 
rear of the pedestal is not installed.  The cover 
plate must be installed on the unit if your stove 
is located in a mobile home or if using outside 
air from the bottom.
OPERATING  
INSTRUCTIONS
With your unit now correctly installed and safety 
inspected by your local authority, you are now 
ready to start a fire.  Before establishing your 
first fire, it is important that you fully understand 
the operation of your draft control.
WARNING
Fireplace Stoves equipped with doors 
should be operated only with doors fully 
open or doors fully closed. If doors are 
left partly open, gas and flame may be 
drawn out of the fireplace stove open-
ing, creating risks from both fire and 
smoke.
When  operated  with  doors  open  the 
manufacturer  supplied  screen  must 
be used.
FIRST FIRE
When  your  installation  is  completed  and  in-
spected you are ready for your first fire.
1)  Open control fully.
2)  Open firebox door and build a small fire us-
ing paper and dry kindling on the firebrick 
hearth.  Secure door on the firebox and wait 
a few minutes for a good updraft in the flue to 
establish the fire.  (Leaving the door slightly 
open will help your fire start more rapidly.)
  CAUTION:    Never  leave  unit 
unattended  if  door  is  left  open.  
This  procedure  is  for  fire  start-up 
only, as unit may overheat if door 
is left open for too long.
3)  With the draft still in the fully open position 
add two or three seasoned logs to your  fire. 
Form a trench in the ash bed to allow air to 
reach the rear of the firebox prior to closing 
the door.