Regency Freestanding Woodstove
9
Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed 
with a listed double wall connector to the ceiling level. 
Note:  Minimum alcove ceiling height - 84"
 
  Maximum depth of alcove - 36"
Floor Protection
A combustible floor must be protected by non-combustible 
material (like tile, concrete board, or certified to UL-1618 or 
as defined by local codes) extending beneath the heater and 
a minimum of 6" (152mm) from each side and minimum 16" 
(406mm) from the front face of the stove and minimum 6" 
(or the rear clearance to combustibles whichever is smaller) 
from the rear of the stove. 
When installed with horizontal venting, non-combustible floor 
protection must beneath the flue pipe and extend 2" (51mm) 
beyond each side.
    Minimum Overall Width (X) of Floor 
       Protector for all installations: 
 Stove 
F2400M 
36" (914 mm)
 Step Stove 
S2400M 
36" (914 mm)
  Minimum Overall Depth (Y) of Floor Protector
 
              
       Residential                           Residential                      Mobile Home                    Alcove
                         Unit                             "C" Vent                          Close Clearance               Close Clearance
                                                          
 
                   Y                    Z                    Y  
          Z 
                Y                     Z 
   Z
  Medium F2400M
          with Airmate             46" (1168 mm)   6" (152 mm)  45"* (1143 mm)  5" (127 mm)    45" (1143 mm)  5" (127 mm)   45"* (1143)  5" (127 mm)
         with Rear Deflector   46" (1168 mm)   6" (152 mm)  45"  (1143 mm)  5" (127 mm)    45" (1143 mm)  5" (127 mm)   45"  (1143)  5" (127 mm) 
 
  Medium S2400M               46" (1168 mm)   6" (152 mm)  45"* (1143 mm)  5" (127 mm)    45" (1143 mm)  5" (127 mm)   45"* (1143)  5" (127 mm)
   - Step Stove 
 
*The rear clearance to combustibles is less than 6" (, for corner installations the rear corners may be angled to take advantage of the closer clear-
ances.
INSTALLATION 
                           
 
          From                                  From Flue                       Min.                    Min.Hearth 
 
Unit 
         Unit                                Center-line                      Width                  to Rear Wall 
 
                                              G                        H 
              I                      J                         K                         L
  Medium F2400M 
with Airmate              15" (381 mm)     5.5" (139 mm)   27" (685 mm)     12" (304 mm)    54" (1371 mm)   48" (1219 mm)
 
with Rear Deflector   15" (381 mm)   6.5" (165 mm)     27" (685 mm)     13" (330 mm)    54" (1371 mm)    49" (1244 mm)
  Medium S2400M Step Stove                       15" (381 mm)      5.5" (139 mm)     27" (685 mm)     12" (304 mm)    54" (1371 mm)   48" (1219 mm)
NOTE: In Canada, floor protection must extend 18" (450mm) to the 
front and 8" (200mm) to each side and back of the stove.