INSTALLATION 
PRECAUTIONS
These venting systems are engineered 
products that have been designed and 
tested for use with the U39-NG1, and 
U39-LP1. The warranty will be voided 
and serious fi re, health or other safety 
hazards may result from any of the following 
actions:
1)  Installation of any damaged Direct Vent 
component
2) Unauthorized 
modifi cation of the Direct 
Vent System
3)  Installation of any component part not 
manufactured or approved by Simpson 
Dura-Vent or Fireplace Products 
International Ltd.
4)  Installation other than as instructed 
by Simpson Dura-Vent and Fireplace 
Products International Ltd.
Warning:  Always maintain 
required clearances (air spaces) 
to nearby combustibles to 
prevent a fi re hazard. Do not fi ll 
air spaces with insulation. 
Be sure to check the vent termination 
clearance requirements from decks, 
windows, soffi ts, gas regulators, air supply 
inlets and public walkways as specifi ed 
in the "Exterior Vent Terminal Locations" 
section in your local building codes.
The gas appliance and vent system 
must be vented directly to the outside 
of the building, and never be attached 
to a chimney serving a separate solid 
fuel or gas-burning appliance.
 Each 
direct vent gas appliance must use it's 
own separate vent system. Common vent 
systems are prohibited.
SAFETY 
PRECAUTIONS FOR 
THE INSTALLER
1) 
Wear gloves and safety glasses for 
protection.
2) 
Exercise extreme caution when using 
ladders or on roof tops.
3) 
Be aware of electrical wiring locations 
in walls and ceilings.
INSTALLATION
RIGID PIPE VENTING ARRANGEMENTS
Vertical Termination Systems for 
Residential Manufactured and 
Mobile Homes
The shaded area in the diagram below shows all 
allowable combinations of straight vertical and 
offset to vertical runs with vertical terminations.
 
Maximum two 45
o
 elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 
9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile) 
Homes after fi rst sale.
Horizontal Terminations for All 
Venting Systems
The shaded areas in the diagram below show 
all allowable combinations of vertical runs 
with horizontal terminations.  Maximum one 
90
O
 elbow (two  45
elbows equal one 90
o
 
elbow).
Propane and Natural Gas: 
Residential, Manufactured and 
Mobile Homes Installations
The venting arrangements diagrammed below, 
have a min. of 75% (fl ue loss) effi ciency with Fan 
Off, as required for manufactured homes. (Actual 
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile) 
Homes after fi rst sale.
Vent Restrictor Position
To set the Vent restriction as 
indicated in the diagram, simply 
loosen the screws and push the 
vent restrictor plate to the correct 
position. Tighten the screws.
Vent Restrictor setting at 
38,000 Btu/h
Vent Restrictor setting at 
30,000 Btu/h