Regency U39-LP1 ユーザーズマニュアル

ページ / 44
Regency
®
 U39 ULTIMATE Direct Vent Freestanding Gas Stove
23
U39-NG1: For 0 to 2000 feet altitude
U39-LP1: For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:
 
            Natural Gas    Propane
 
Burner  
 #32 
       #50 
 
            
Max. Input - Natural Gas/Propane 
 
  
38,000 
Btu/h
Min. Input -  Natural Gas/Propane
  
20,000 
Btu/h
  
Supply Pressure   
 
Natural Gas 
min.  5" w.c.
 Propane 
min. 
12" 
w.c.
Manifold Pressure
 
Natural Gas 
3.8" 
+/- 0.2" w.c.
 Propane 
11" 
+/- 
0.2" 
w.c.
Electrical: 120 V. 1.13A  60Hz.
Circulation: Variable speed fan, 125/75 
CFM.
Log Set: Ceramic fi ber, 7 per set.
System Data: 
HIGH ELEVATION - U39-NG1
For 2,000 - 4,500 feet altitude
  
Burner Inlet Orifi ce Sizes: 
 Natural 
Gas Burner 
#33 
 
 
Max. Input Rating  36,100 Btu/h         
Min. Input Rating  19,000 Btu/h
   
        
System Data
U39 Converted to 30,000 Btu
For 0 to 4500 feet altitude
Burner Inlet Orifi ce Sizes:
 
            Natural Gas 
   Propane
 
Burner  
  #37 
      #52
  
Max. Input - Natural Gas/Propane
  
30,000 
Btu/h 
Min. Input - Natural Gas/Propane
  
15,000 
Btu/h
Supply Pressure   
 
Natural Gas 
min.  5" w.c.
 Propane 
min. 
12" 
w.c.
Manifold Pressure
Natural Gas 
3.8"    +/- 0.2" w.c.
Propane 
11"     +/- 0.2" w.c.
Electrical: 120 V. 1.13A  60Hz.
Circulation: Variable speed fan, 125/75 
System Data
U39 with 40,000 BTU
GAS CONNECTION
The gas connection is a 3/8" NPT 90
o
 elbow. 
The gas line can be rigid pipe or to make 
installation easier, use a listed fl exible connector 
and/or copper tubing if allowed by local codes. 
Since some municipalities have additional local 
codes it is always best to consult with your local 
authorities and the CAN/CGA B149 installation 
codes.
For USA installations follow local codes and/or 
the current National Fuel Gas Code, ANSI 
Z223.1.
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so that 
gas lines can be easily disconnected for burner 
and/or valve servicing. Flare nuts for copper lines 
and fl ex connectors are  usually considered to 
meet this requirement.
Important: Always check for gas leaks with a 
soap and water solution or gas leak detector. 
Do not use open fl ame for leak testing.
Note:  Prior to any pressure testing of the gas 
supply piping system that exceeds 
test pressures of 1/2 psig, this 
appliance must be disconnected from 
the piping system.  If test pressures 
equal to or less than 1/2 psig are used 
then this appliance must be isolated 
from the piping system by closing 
its individual manual shut-off valve 
during the testing.
HIGH ELEVATION
This unit (at 38,000 Btu/h) is approved in Canada 
for altitude 2000 ft. to 4500 ft. (CAN/CGA-2.17-
M91) with the orifi ce kit Part # 621-975. For 
Natural Gas installations above 4500 ft. follow 
current CAN/CGA-B149.1.
In U.S.A., for installations above 2000 ft. refer 
to current ANSI Z223.1 Sc8-8.1.2a appendix F, 
for resizing orifi ce.
INSTALLATION
Diagram 9
9)  Slide the Wall Thimble Cover (Part # 940) 
over the Retro Connector and secure with 
masonry bolts. Diagram 10. If you have a 
framed wall in front of the masonry, use wood 
screws to mount the Wall Thimble Cover to 
the framed wall, over the Retro Connector 
and the 10" (254mm) square framed opening. 
Diagram 11. If needed, add a section of 
direct vent pipe to the Retro Connector in 
order to extend through the opening in the 
Wall Thimble Cover.
Diagram 10
Diagram 11
10) The connection between the appliance and 
the Retro Connector may be completed with 
a section of black direct vent pipe, together 
with an adjustable length pipe section.