REMOVING VALVE
2)  Undo the six screws holding the control 
panel in place.
3)  Disconnect all wires from the back of the 
panel and then remove panel.  You should 
lay the panel on a soft cloth so it doesn't get 
marked up.  See diagram below.
6)  Remove the two outside frame pieces by 
removing two screws per side.  See diagram 
below.
7)  At this point you should disconnect the gas 
at the valve. You can access it through the 
front now that the control panel is off, or you 
can access it through the rear pedestal cover 
plate.
8)  Carefully remove the logs and lava rock.
9) Remove 
burner. 
If your valve requires maintenance or replace-
ment,  use the following instructions:
Note: Always close off the gas supply 
before removing the valve.
1)  Open front pedestal door.  You may want 
to put a soft cloth on the base of the unit 
so that when the pedestal door is open it 
doesn't scratch the paint.  
Note:  Use a magnetic type screwdriver if 
possible.
10) Remove all 18 screws holding the burner 
tray assembly in place.
11) Carefully lift the burner tray assembly out.
12) To replace the burner tray assembly, simply 
reverse these instructions.  
MAINTENANCE
5)  Disconnect the DC spark generator wires 
from the valve.
4)  Remove the screw that holds the DC 
spark generator wires in place on the 
valve.