Regency SC100L ユーザーズマニュアル

ページ / 28
Regency Freestanding Woodstove
12
INSTALLATION
                                   TABLE 1
MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET
(Measured from the top of the unit)
                             
  # OF ELBOWS
      ELEVATION (FT)
    ABOVE SEA LEVEL
                      0       2 x 15
o
  4 x 15
o
   2 x 30
o
    4 x 30
o
  2 x 45
o
   4 x 45
o
 0-1000
12.0
13.0
14.0
15.0
18.0
16.0
20.0
1000-2000
12.5
13.5
14.5
15.5
19.0
16.5
21.0
2000-3000
13.0
14.0
15.0
16.0
19.5
17.0
21.5
3000-4000
13.5
14.5
15.5
17.0
20.0
18.0
22.5
4000-5000
14.0
15.0
16.0
17.5
21.0
18.5
23.0
5000-6000
14.5
15.5
17.0
18.0
21.5
19.0
24.0
6000-7000
15.0
16.0
17.5
18.5
22.5
20.0
25.0
7000-8000
15.5
16.5
18.0
19.0
23.0
20.5
25.5
8000-9000
16.0
17.0
18.5
20.0
24.0
21.0
26.5
9000-10000
16.5
17.5
19.0
20.5
24.5
22.0
27.0
NOTE: No more than two offsets (four elbows) allowed. Two 45
o
 elbows equal one 90
o
 elbow.
MOBILE HOME INSTALLATION
RECOMMENDED
HEIGHTS FOR
WOODSTOVE FLUE
Simple rules on draft. See Table 1.
1) At sea level minimum height is 12' straight.
2) Add the following vertical height to com-
pensate for:
45 deg. elbow = 1 ft.
90 deg. elbow = 2 ft.
"T"
= 3 ft.
Each foot of horizontal run = 2 ft.
3) Add 4% overall for each 1000' above sea
level.
Example: a)
1-1/2 ft. of horizontal run
= 3 ft.
one "T"
= 3 ft.
Total Addition (at sea level)
= 6 ft.
Example: b)
One 90 deg. elbow
= 2 ft.
2 ft. of horizontal run
= 4 ft.
one "T"
= 3 ft.
Total Addition (at sea level)
= 9 ft.
Recommended Flue Height
   Elevation     Example a)        Example b)
0'
18'
21'
1000'
18.72'
21.84'
2000'
19.44'
22.68'
5000'
21.60'
25.20'
8000'
23.76'
27.72'
Once you have properly marked the position of
your unit and the floor protection as outlined in
the Residential Installation items #1 through #8,
a supply of fresh air has to be supplied to your
unit. Cut a minimum 4 inch diameter hole through
your floor protector and the floor directly under
your pedestal base to the outside.  Use 4" duct
pipe with a mesh grill to pipe fresh air into the
pedestal area. Block off the hole in the back of
the pedestal with the square plate and the two
1/2" screws provided.
Place your unit in position and secure it to the
floor using two lag bolts 3/8" x 3-1/2" through
the two holes inside the pedestal base.  It is
important to maintain the structural integrity of
the Mobile Home floor, walls and roof when
installing your unit.
For Mobile Home units installed in the U.S. the
unit must be grounded using a #8 ground wire
with approved termination and star washer.
4) Install the two front air tubes into the holes