Regency S2400M ユーザーズマニュアル

ページ / 28
Regency Freestanding Woodstove
7
INSTALLATION
RESIDENTIAL  
INSTALLATION
1)  Please read this entire manual before you 
install and use your new woodstove. Failure 
to follow instructions may result in property 
damage,  bodily  injury  or  even  death.  Be 
aware  that  local  Codes  and  Regulations 
may override some items in this manual. 
Check with your local inspector.
2)  Select a position for your Regency Stove. 
Consult  the minimum  clearance  chart for 
your model and set the stove in place. For 
close clearance installation use listed double 
wall connector systems.
3)  To  insure  vertical  alignment,  suspend  a 
plumb bob from the ceiling over the exact 
center of your stove flue and mark a spot 
on the ceiling to indicate the center of the 
chimney.
4)  Check  that  the  area  above  the  ceiling  is 
clear for cutting. Re-confirm the clearance 
from  the  stove  to  combustibles  to  insure 
that they are within the prescribed limits.
5)  This  woodstove  must  be  connected  to  a 
UL 103 HT (ULC S629) listed chimney or 
a code approved masonry chimney with a 
flue liner.
6)  Install chimney according to chimney manu-
facturers instructions. The performance of 
your woodstove is governed to a very large 
part  by  the  chimney  system. Too  short  a 
chimney can cause difficult start-up, dirty 
glass, back smoking when door is open, and 
even reduced heat output. Too tall a chimney 
may prompt excessive draft which can result 
in very short burn times and excessive heat 
output. The use of an inexpensive flue pipe 
damper may be helpful in reducing excessive 
draft.
 
CAUTION: The chimney should be the same 
size as the 6" flue outlet on the stove. The 
chimney must be listed as suitable for use 
with solid fuels. For other types of chimneys 
check with your local building code officials. 
Do not confuse a chimney with a type “B” 
Venting  System  used  for  gas  appliances 
as suitable for a wood burning appliance. 
For Mobile Home installations refer to that 
section within this manual.
7)  Mark the location of the pedestal base or legs 
on the floor, then move the stove aside and 
mark the position of the floor protector.
8)  The floor protector must be of non-combus-
tible material and must extend 16" (406mm)  
in front of the door opening and 6" (152mm) 
to the sides and rear of the unit.  Some areas 
may  require  a  larger  size  floor  protector.  
See  your  local  inspector.    For  outside  air 
installation refer to Mobile Home installation 
instructions within this manual.
9)  When the floor protection is complete, posi-
tion the stove with the flue collar centered 
under the installed chimney.
10) In seismically active areas, Regency rec-
ommends that your unit is secured to the 
floor by using the bolt down holes inside 
the pedestal (the same ones used in Mobile 
Home installations).
11) For  residential  installations  using  6"  "C" 
Vent  (single  wall)  the  chimney  connector 
must be at least 24 gauge steel. Do not use 
galvanized pipe. For Mobile Home instal-
lation refer to the Mobile Home installation 
instructions within this manual.
12) Do not connect this unit to a chimney 
serving another appliance.
13) A chimney connector cannot pass through 
an  attic  or  roof  space,  closet  or  similar 
concealed  space,  or  a  floor,  ceiling,  wall 
or  partition  of  combustible  construction. 
In  Canada,  if  passage  through  a  wall,  or 
partition  of  combustible  construction  is 
desired,  the  installation  shall  conform  to 
CAN/CSA-B365, Installation Code for Solid-
Fuel-Burning Appliances and Equipment.
14) Your Regency Woodstove is not to be con-
nected to any air distribution duct.
Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects 
or other reproductive harm.
NOTE:  In  Canada,  floor  protection  must 
extend 18" (450mm) to the front and 
8" (200mm) to each side and back 
of the stove.
MODULAR INSTALLATION OPTIONS
Modular Part
Things to consider when choosing options:
Modular Option
Blower/Fan
Ash Drawer Kit
Screen Door
OPTIONS: These can be installed at time of installation or added later:
F2400M
Airmate OR 
Rear Heat Deflector
F2400M, S2400M
Pedestal OR
Legs
Things to consider when choosing options
The following items are required when assembling your Regency Stove.  F2400M unit - the Rear Heat Deflector is supplied with the stove, but if 
you choose not to use it you must use the Airmate instead.  
Clearances are different. See the Minimum Clearance to Combustible Materials chart in the Installation section of this 
manual. Generally you can get closer clearances with the airmate than with the rear heat deflector.
Convection heat with Airmate vs. Radiant Heat with Rear Heat Deflector. The airmate pushes heat forward and into the 
room, the rear heat deflector deflects the heat upward. Refer to the Installation section within this manual.
There are no performance differences with either the pedestal or legs.  It is primarily a personal preference.  Legs can 
be either painted steel, painted cast, or gold plated cast.  
Leg installation requires the bottom shield (refer to Leg and Bottom Shield Assembly, Installation section).
Adding the blower will increase the area heated by the stove, it can move warm air beyond the room where the stove 
is installed (refer to Blower/Fan, Installation section).
Adding the Ash Drawer Kit makes cleaning ashes out of the stove easier and cleaner (refer to Bottom Shield Ash 
Drawer Kit, Installation section).
A simple add-on option that will allow you to enjoy the sound, warmth and view of an open fire.