19
LOG  SET
INSTALLATION
Read  the  instructions  below  carefully
and  refer  to  the  diagrams.    If  logs  are
broken  do  not  use  the  unit  until  they  are
replaced.  Broken  logs  can    interfere  with
the  pilot  operation.
The gas log kit contains the following:
a) 02-65 Rear Log
b) 02-56 Middle Left Log
c) 02-44 Front Left Log
d) 02-46 Left Top Log
e ) 02-45 Front Right Log
f) 02-47 Center Log
g) 02-48 Middle Right Log
h)
Embers
i)
Lava
Note: Install  Optional  Brick  Panels  prior
to  installing  logs.
Embers.
Embers
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
1) Carefully remove the logs from the box and
unwrap them.  The logs are fragile, handle
with  care  -  do  not  force  into  position.
2) Sprinkle  the  embers  on  the  left  and  right
sides of the firebox base.
INSTALLATION
CONVERSION TO LOWER BTU RATING
THIS CONVERSION MUST BE DONE BY AN AUTHORIZED
GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION
!!
NG  Conversion  Kit  730-920
Contains:
Qty. Part # Description
1 904-240 Burner Orifice #37 (NG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
LPG  Conversion  Kit  730-922
Contains:
Qty. Part # Description
1 904-390 Burner Orifice #52 (LPG)
1 918-034 Decal "Converted to 30,000 Btu"
1 918-033 Instruction Sheet
Additional  Piece  (pkg.  with  unit:
1
Log Bracket Restrictor
1) Shut off the gas supply.
2) Open the front door.  Carefully remove the
logs and lava rock.
3) Remove burner. See diagram below.
Burner  Orifice
4) Unscrew the 2 Rear
Log Pins and move
to the front hole po-
sition.
5) Remove  Rear  Log
Bracket and slide the
Log  Bracket  Re-
strictor between the
Position  the  Log  Bracket  Restrictor  between
the Rear Log Bracket and the burner.
6) Remove burner orifice  with a 1/2" spanner
and  discard.
7) Reinstall new burner orifice (NG stamped
#37 or LPG stamped #52) and tighten.
8) Reverse steps 3) and 2).
9) Adjust Flue restrictor setting: To set the Flue
restriction as indicated in the diagram, sim-
ply  loosen  the  screws  and  push  the  flue
restrictor plate to the correct position. Tight-
en  the  screws.
Unit Btu/h
Restrictor Opening
FG3940 Mj/h
A 45mm
31 Mj/h
B 35mm
Note: Use a
magnetic  type
screwdriver  if
possible.
Rear Log Bracket and the burner, secure
with  the  2  screws.
Flue  Restrictor
setting at High Btu/h
Flue  Restrictor
setting at Low Btu/h
10) Attach the label  "This unit has been con-
verted to..." on top of the data badge over
the higher Btu information.
11) Check for gas leaks.
12) Check inlet and outlet pressures.
13) Check operation of flame control.  Check for
proper flame appearance and glow on logs.