FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
System Data - FG37
Burner  Inlet  Orifice  Sizes:
    NG
#37
LPG
#52
Max.  Input  Rating
31.7 mj
Min.  Input  Rating
16 mj
Supply  Pressure
NG
min. 1.13 kPa
LPG
min. 2.75 kPa
Manifold  Pressure
NG
.89 kPa
LPG
2.55 kPa
GAS  CONNECTION
The gas connection is a 1/2" (13mm) NPT Male
Thread. Copper  can  be  used  or  other  con-
nections approved by AG 604.
When  using  copper  or  flex  connectors  use
only approved fittings. Always provide a union
so that gas lines can be easily disconnected for
burner  and/or  valve  servicing.  Flare  nuts  for
copper lines are  usually considered to meet
this requirement.
Important:  Always  check  for  gas  leaks
with  a  soap  and  water  solution  or  gas
leak  detector.  Do  not  use  open  flame  for
leak  testing.
Note: Prior to any pressure testing of
the gas supply piping system that
exceeds test pressures of 3.45
kPa, this appliance must be dis-
connected from the piping sys-
tem.  If test pressures equal to or
less than 3.45 kPa are used then
this appliance must be isolated
from the piping system by clos-
ing its individual manual shut-off
valve during the testing.
VERTICAL  TERMINATION  WITH
CO-LINEAR  FLEX  SYSTEM
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING
A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm) co-linear aluminium flex running the
full length of the chimney. See the Fluing Arrangements chart on page 9 for minimum and maximum
flue lengths. See chart  below for minimum distances from roof. Periodically check that the flue
is  unrestricted.
Masonry  chimneys  may  take  various  contours  which  the  flexible  liner  will  accommodate.
However,  keep  the  flexible  liner  as  straight  as  possible,  avoid  unnecessary  bending.
The Air Intake pipe must  be attached to the inlet air collar of the termination cap.
Required  Parts:
Part #
Description
946-529
Co-linear DV Vertical Termination Cap
948-305
3" Flex - 35 ft.
640-994
FG37 Dura-Vent Adapter
946-563
Co-Axial to Co-Linear Adapter Kit
which  contains  the  following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Approved  Caps
980
Vertical Termination Cap
923GK
3" (76mm) Co-linear Adapter
with  flashing
923GK
3" (76mm) Co-linear Adapter
with  flashing
INSTALLATION