FG37 Regency Rear Flued Room Sealed Freestanding Gas Heater
9
INSTALLATION
FLUING ARRANGEMENTS  -  VERTICAL  TERMINATIONS
FOR  BOTH  RESIDENTIAL  &  MANUFACTURED  HOMES/MOBILE  HOMES
Offset to Vertical Terminations
If  connecting to a  Dura-Vent sys-
tem,    the  Adapter  to  Dura-Vent  #
640-994  is  required.
Vertical Terminations
with Co-linear Flex System
The shaded  area in the diagram  shows the allowable  vertical
terminations  installed  in  a  masonry  chimney.  All  vertical    flue
installations require the Flue Restrictor to be set to 32mm open. All
Vertical Flue Terminals must be Simpson Dura Vent (Abey Australia)
DV 980 MAS (Australian Modified.)
Vertical Terminations
using Dura-Vent Fluing System
The  shaded  areas  in  the  two  diagrams  below  show  all  allowable
combinations  of  straight  vertical  and  offset  to  vertical  runs  with
vertical  terminations.  Maximum    one  90
o
  elbow.    All  vertical  and
offset to vertical flue installations require Flue Restrictor to be set to  32mm
open. If the flue is ENCLOSED in a chase (min. size 229mm x 229mm)
maintain a  32mm clearance to combustibles. All Vertical Flue Terminals
must be Simpson Dura Vent (Abey Australia) DV 980 MAS (Australian
Modified.)
Straight Vertical Terminations
Flue Restrictor Position
Vent Restrictor
Vent
Restrictor
Plate
Vent Restrictor
(fully open)
Vent
Restrictor
Plate
44.5mm
44.5mm
32mm
32mm
To  set  the  Flue  restriction
as indicated in the diagram,
simply  loosen  the  screws
and push the flue restrictor
plate to the correct position.
Tighten  the  screws.
216mm
9.1m
Max.
3.2m
Min.
1
1
1
2
4
5
6
7
8
2
1
3
9
Horizontal Distance (meters)
V
ertical
Height
(meters)