Regency U39 ULTIMATE Direct Vent Freestanding Gas Stove
Horizontal Venting with Two (2) 90
o
 Elbows
 Option     V
         H + H1
     A)
3'  Min.      2' Max.
     B)
5'  Min.      3' Max.
     C)
8'  Min.      4' Max.
With these options, maximum total
pipe length is 30 feet with minimum
of 8 feet total vertical and maximum
4 feet total horizontal.
Please note minimum 1 foot
between 90
o
 elbows is required.
INSTALLATION
One 90
o
 elbow = Two 45
o
 elbows.
Vertical Venting with Two (2) 90
o
 Elbows
Option V
    H
   V1
V + V1
     A)
1' Min.
1' Max.
1' Min.
2' Min.
     B)
1' Min.
2' Max.
2' Min.
3' Min.
     C)
2' Min.
3' Max.
2' Min.
4' Min.
     D)
2' Min.
4' Max.
2' Min.
4' Min.
With these options, max. total pipe length is 30 feet
with min. of 4 feet total vertical and max. 4 feet total
horizontal.
Please note min. 1 foot between 90
o
 elbows is
required.
One 90
o
 elbow = Two 45
o
 elbows.
Vent restrictor position A (fully
open), refer to page 11.
Vent restrictor position A (fully open), refer to
page 11.
Lengths do not include  elbow
indicated
Lengths do not include elbow indicated