E33 FPI Direct Vent Gas Insert
MAINTENANCE
GENERAL VENT 
MAINTENANCE
Conduct an inspection of the venting system 
semi-annually. Recommended areas to inspect 
as follows:
1)  Check the Venting System for corrosion in 
areas that are exposed to the elements. 
These will appear as rust spots or streaks, 
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2)  Remove the Termination Cap, and shine a 
fl ashlight down the Vent. Remove any bird 
nests, or other foreign material.
3)  Check for evidences of excessive condensa-
tion, such as water droplets forming in the 
inner liner, and subsequently dripping out the 
joints. Continuous condensation can cause 
corrosion of caps, pipe, and fi ttings. It may 
be caused by having excessive lateral runs, 
too many elbows, and exterior portions of the 
system being exposed to cold weather.
4)  Inspect joints to verify that no pipe sections 
or fi ttings have been disturbed, and conse-
quently loosened. Also check mechanical 
supports such as Wall Straps, or plumbers' 
tape for rigidity.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door to carefully remove the 
logs. The pilot light generates enough heat to 
burn someone. If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagram under Log 
Installation.  
NOTE:  Improper positioning of logs may create 
carbon build-up and will alter the unit’s perform-
ance which is not covered under warranty.
GLASS GASKET
If the glass gasket requires replacement use  
a tadpole gasket for the Flush Front (Part # 
936-155).   
STEEL OR GOLD TRIM
The steel or 24 carat gold plated fi nish on the 
louvers requires little maintenance, and need 
only be cleaned with a damp cloth. DO NOT use 
abrasive materials or chemical cleaners, as they 
may harm the fi nish and void the warranty.
Clean any fi ngerprints off  before turning the 
unit on.   If the top louvers start to discolour, 
check the door gasket seal and replace if 
necessary.
Top view of pilot fl ame
Top View of pilot fl ame
Incorrect fl ame pattern will have small, probably 
yellow fl ames, not coming into proper contact 
with the rear of the burner or thermopile. 
6)  Each time the appliance is lit, it may cause 
condensation and fog the glass.  This 
condensation and fog is normal and will 
disappear in a few minutes as the glass 
heats up.
 
Never operate the appliance without the 
glass properly secured in place or with 
the door open.
7)  Do not use this appliance if any part has been 
under water. Immediately call a qualifi ed 
service technician to inspect the appliance 
and to replace nay part of the control system 
and any gas control which has been under 
water.
8)  Periodically check the pilot fl ames. Correct 
fl ame pattern has three strong blue fl ames: 1 
fl owing around the thermopile and 1 around 
the thermocouple, and 1 fl owing across the 
front of the burner.
Note:  If you have an incorrect fl ame pattern, 
contact your FPI dealer for further 
instructions.
CLOTHING OR OTHER FLAM-
MABLE MATERIAL SHOULD NOT 
BE PLACED ON OR NEAR THE 
APPLIANCE.
WARNING:  CHILDREN AND 
ADULTS SHOULD BE ALERTED 
TO THE HAZARDS OF HIGH 
SURFACE TEMPERATURE AND 
SHOULD STAY AWAY TO AVOID 
BURNS OR CLOTHING IGNITION.  
YOUNG CHILDREN SHOULD 
BE CAREFULLY SUPERVISED 
WHEN THEY ARE IN THE SAME 
ROOM AS THE APPLIANCE.
CAUTION:  ANY SAFETY SCREEN 
OR GUARD REMOVED FOR 
SERVICING AN APPLIANCE 
MUST BE REPLACED PRIOR TO 
OPERATING THE APPLIANCE.
MAINTENANCE 
INSTRUCTIONS
1)  Always turn the gas valve to the off posi-
tion before cleaning. For relighting, refer to 
lighting instructions. Keep the burner and 
control compartment clean by brushing and 
vacuuming at least once a year.
 
When cleaning the logs, use a clean soft 
paint brush as the logs are fragile and easily 
damaged.
2)  Clean (never when unit is hot) appliance, 
door and louvers with a damp cloth.  Never 
use an abrasive cleaner. The optional  fi nish-
es on louvers and doors may be scratched 
if abrasives are used to clean them. The 
heater is fi nished in a heat resistant paint 
and should only be refi nished with heat 
resistant paint (not with wall paint). FPI uses 
StoveBrite Paint - Metallic Black #6309.
3)  Make a  periodic check of the burner for 
proper position and condition. Visually 
check the fl ame of the burner periodically, 
making sure the fl ames are steady: not 
lifting or fl oating. If there is a problem, call 
a qualifi ed service person. 
4)  The appliance and venting system must be 
inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed. 
 
During the annual service call, the burners 
should be removed and cleaned from the 
burner tray. 
5)  Keep the area near the appliance clear and 
free from combustible materials, gasoline 
and other fl ammable vapours and liquids.
Front Burner Tube
Front Burner Tube