E33 FPI Direct Vent Gas Insert
IMPORTANT:  
SAVE THESE 
INSTRUCTIONS
The FPI Gas Fireplace must be installed in  
accordance with these instructions. Carefully 
read all the instructions in this manual fi rst. 
Consult the building authority having jurisdic-
tion to determine the need for a permit prior to 
starting the installation.
NOTE:  Failure to follow the instructions could 
cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re insurance 
and/or warranty. 
FOR YOUR SAFETY
This appliance requires air for proper combus-
tion. Always provide adequate combustion and 
ventilation air.  Follow instructions and informa-
tion in CSA B149.1 (in Canada) or the National 
Fuel Gas Code ANS Z223.1/NFPA (in the USA), 
regarding requirements for combustion and 
ventilation air.
GAS PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than
1/2 psig. (3.45 kPa).
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.
Gas Input Capacity:  
 Natural 
Gas 
38,000 
Btu/h
 Propane 
35,500 
Btu/h
Min. Input:
 Natural 
Gas 
20,000 
Btu/h
 Propane 
19,000 
Btu/h
Fuels:  Approved for use with both natural gas, 
and propane. Approved as is for use at 0' to 
4,500' (0-1370m).
Electrical:            120V A.C. system.
Circulation Fan:  Variable speed, 127 CFM.
Log Set:               Ceramic fi bre, 8 per set.
Vent System:       3" co-linear aluminum fl ex.
INSTALLATION
INSTALLATION INTO A 
SOLID FUEL BURNING 
FIREPLACE OR 
FACTORY BUILT 
FIREPLACE
The E33 Gas Inserts have been tested and ap-
proved to be vented into any masonry fi replace 
or approved solid fuel burning factory built 
fi replace that will allow the insert to physically 
fi t into the fi rebox. Refer to page 6 for minimum 
fi replace clearances.
If the factory built fi replace* height is too low 
for your Insert, you may remove the smoke 
baffl e plate and damper from the factory 
built fi replace as long as these items are 
saved and are reinstalled in the event that 
the Insert is removed. NOTE: Any alterations 
made to the listed solid fuel burning factory 
built fi replace may void the listing of the 
fi replace. Cutting any sheet-metal parts of 
the fi replace, in which the gas fi replace insert 
is to be installed, is prohibited.
If the factory-built fi replace has no gas ac-
cess hole(s) provided, an access hole of 
1.5" (37.5mm) or less may be drilled through 
the lower sides or bottom of the fi rebox in 
a proper workmanship like manner. This 
access hole must be plugged with non-com-
bustible insulation after the gas supply line 
has been installed. 
The fi replace and fi replace chimney must be 
clean and in good working order and con-
structed of non-combustible materials and 
chimney cleanouts must fi t properly. Refrac-
tory, glass doors, screen rails, screen mesh, 
and log grates can be removed from the 
fi replace before installing the gas fi replace 
insert. Smoke shelves, shields and baffl es 
may be removed if attached by mechani-
cal fasteners. A tight connection between 
the gas fi replace insert fl ue collar and the 
fi replace chimney must be made.
*Check with your local inspector before com-
mencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:
General Safety Information
1)  The appliance installation must conform 
with local codes or in the absence of local 
codes, with CAN/CSA B149.1 (in Canada) 
or the National Fuel Gas Code ANSI Z223.1 
NFPA 54 in the U.S.A. This appliance should 
be installed by a qualifi ed gas fi tter technician 
only.
2)  Installation and repair should be done 
by a qualifi ed service person.  
3)  The appliance should be inspected 
before use and at least annually by a 
professional service person. More fre-
quent cleaning may be required due to 
excessive lint from carpeting, bedding 
material, animal hair, etc.  It is impera-
tive that control compartments, burners 
and circulating air passageways of the 
appliance be kept clean. 
4)  See general construction and assembly 
instructions. This appliance may only be 
installed in a vented, noncombustible fi re-
place.
5)  This appliance is Listed for bedroom  instal-
lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  Always connect this appliance to a vent 
system vent that is run (or routed) to the 
outside of the building envelope. Never vent  
to another room or inside a building. Make 
sure that the vent is properly sized and is 
of adequate height to provide the proper 
draft.  
7)  Inspect the venting system annually for 
blockage and any signs of deterioration.   
8)  Any glass removed for servicing must be 
replaced prior to operating the appliance.  
9)  WARNING: Failure to position the parts 
in accordance with the diagrams in this 
manual or failure to use only parts specifi -
cally approved with this appliance may 
result in property damage or personal 
injury.
10) To prevent  injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.