CB 1200 Pellet Stove 
5.  Disposal of Ashes
•  Frequency:
  As needed
•  By:  Homeowner
Ashes  should  be  placed  in  a  metal  container  with  a 
tight-fitting lid.  The closed container of ashes should 
be placed on a non-combustible floor or on the ground, 
well away from all combustible materials, pending final 
disposal.  
If the ashes are disposed of by burial in soil or otherwise 
locally  dispersed,  they  should  be  retained  in  the 
closed container until all cinders have been thoroughly 
cooled. 
6.  Cleaning Heat Exchanger Chambers & Drop Tube
•  Frequency:
  Weekly or every 1 ton of fuel
•  By:  Homeowner
The  amount  of  ash  buildup  in  the  firepot  will  be  a  good 
guide  to  determine  how  often  you  should  clean  the  heat 
exchangers. 
 
a.  Allow the appliance to completely cool down before 
pulling the cleaning rods.
  Turn the thermostat on and 
then immediately off to start the exhaust blower on its 
cycle time.  It will pull fly ash out the exhaust instead 
of into the room.
  b.  To access the cleaning rods lift the hopper lid.  Both  
black bent handle pull rods are located close to the 
face of the appliance to the left and right side.
  c.  To  clean,  pull  the  rods  straight  out  until  it  stops, 
approximately  20  inches  (508mm).    Slide  the  rods 
OUT and IN a couple of times.
WARNING
Heat exchanger cleaning rods may be warm 
to the touch.  For safety purposes wear 
gloves.
Do not pull heat exchanger cleaning rods 
while appliance is operating.
Push cleaning rods IN when done, DO NOT 
leave cleaning rods OUT.  Injury can occur.
2.  Cleaning Firepot with Cleaning Rod & Firepot 
Scraper
•  Frequency:  Daily or more often as needed
•  By:  Homeowner
  a. Be  sure  the  appliance  is  allowed  to  cool,  has  been 
unplugged and the exhaust blower is off.  If you are 
just cleaning the firepot, there is no need to unplug the 
appliance.
  b. Pull firepot cleaning rod OUT and IN a couple of times 
to help shake debris loose.   If rod is hard to pull, it may 
be necessary to use your firepot clean-out tool to chip 
away material that has built up on the bottom plate of 
the firepot and to push out any clinkers.  Larger clinkers 
may have to be removed from the top of the firepot.  
Corn clinkers can be especially difficult to break up.
  c. The  firepot  floor  plate  must  be  fully  closed  when 
finished.  
See Figure 27.1 on page 27
4.  Cleaning Ash Pan
•  Frequency:
  Weekly or every 5 bags of fuel
•  By:  Homeowner
  Locate the ash pan underneath the firepot and using a 
slight pull up and out remove the ash pan.  Empty into 
a  non-combustible  container  and  re-install  ash  pan. 
See Disposal of Ashes.
3.  Ash Removal from Firebox
•  Frequency:
  Weekly or more frequently depending on 
ash build-up.
•  By:  Homeowner
 
a.  Allow the appliance to completely cool down. There 
must  not  be  any  hot  ashes  in  the  firebox  during 
cleaning.
  Turn the thermostat on and then immediately 
off to start the exhaust blower on its cycle time.  It will 
pull fly ash out the exhaust instead of into the room.
  b. Frequent cleaning of the ash in the firebox will help 
slow down the build-up of ash in the exhaust blower 
and vent system.
  c. Open door.  Remove ash with an ash vacuum or whisk 
broom and small dust pan.
  d.  This  ash  is  deposited  in  the  same  ash  pan  as  the 
firepot debris. The ash pan should be emptied every 
time you clean the firebox.  Remember to place the ash 
and debris into a metal or non-combustible container.  
 
See Disposal of Ashes.
 
WARNING
•  NEVER pull firepot cleaning rods or cleaning 
slide plates when appliance is operating.  Hot 
pellets may fall into ashpan and may start a 
fire or have mis-starts due to lack of vacuum.
Fire Risk.
Disposal of Ashes
WARNING
•  Ashes  should  be  placed  in  metal  container 
with tight fitting lid.
•  Ashes should be retained in closed container 
until all cinders have thoroughly cooled.