Stove Installation 
(for qualified installers only)
Travis Industries
100-01140
4 020628
Alcove Installation Requirements
Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered
an alcove installation.  Because of the reduced height, the special installation requirements listed
below must be met.
Chimney connector and chimney must be one of the following types:
• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney
• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors
Rainier-45°
Rainier-90°
Minimum Clearance
(See the illustration below)
Combustible
Alcove
Non-Combustible
Alcove
Combustible
Alcove
Non-Combustible
Alcove
A
Sidewall to stove
16"
6"
14"
6"
B
Backwall to stove
14"
4"
9 1/2"
2"
D
Connector to sidewall
25 1/2"
15 1/2"
23 1/2"
15 1/2"
E
Connector to backwall
10"
2"
10 1/4"
2 3/4"
G
Maximum depth of alcove
48"
48"
48"
48"
H
Minimum width of alcove
57 3/4"
37 3/4"
53 3/4"
37 3/4"
J
Minimum height of alcove
84"
6" above stove top
84"
6" above stove top
Alcoves are classified as combustible or non-combustible.  Non-combustible alcoves must have
walls and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete).
This non-combustible material must be spaced and ventilated at least 1" off of all combustible
materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling.
All other alcoves are considered combustible.  The clearances below must be met:
Non-combustible alcove 
construction (on walls 
and ceiling) - see the 
explanation above.
AA
AA
AA
AA
3 1/2" thick non-
combustible 
material
Combustible 
materials 
1" Min.
Ventilated 
air space
Non-combustible 
reinforcer
a
b
d
e
h
j
g