Enviro C-11023 ユーザーズマニュアル

ページ / 36
The combustion exhaust blower is a variable speed blower controlled by the heat output button. This 
blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down. 
The  vacuum  pressure  inside  the  firebox  will  increase  as  the  combustion  exhaust  blower  increases  in 
speed (higher heat output setting).
If the fire should happen to go out and the heat output indicator has been set on the lowest setting, the 
Slider Damper should be pushed in slightly, decreasing the air in the firebox.
If, after long periods of burning, the fire builds up and overflows the burn pot or there is a build up of 
clinkers, this would be a sign that the pellet quality is poor, this requires more primary air, the slider 
damper must be pulled out to compensate.  Pulling the slider damper out gives the fire more air.
The easiest way to make sure that an efficient flame is achieved is to understand the characteristics of 
the fire.
•  A tall, lazy flame with dark orange tips requires more air – Open slider (pull out) slightly.
•  A short, brisk flame, like a blowtorch, has too much air – Close slider (push in) slightly.
•    If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame 
with no black tips then the air is set for proper operation.
SPECIAL NOTES:
Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture 
content or ash content the fire will be less efficient and has a higher possibility of the fire building up and 
creating clinkers (hard ash build-up).
Taking a reading of vacuum pressure inside the firebox with a magnehelic gauge can be used to set 
the slider for best combustion. The best settings are a reading of approximately 0.10 inches of 
water column on the high fire setting.  Some fuels may require higher or lower settings. The 
reading can be taken from the 1⁄8” (3 mm) hole located on the front of the unit below the door and behind 
the magnetic ash lip.
Installation
S
LIDER
/D
AMPER
 S
ET
-U
P
:
This is used to regulate the airflow through the pellet stove. T
Air Intake Box
Exhaust Channel
Slider Damper
Exhaust Blower
26
Figure 29: Slider/Damper Plate in Unit.
The  slider  damper  is  located 
behind  the  left  side  panel. 
To  open  the  left  side  panel, 
undo  the  one  screw  located 
in  the  upper  front  corner  of 
the  cabinet  side  between  the 
louvers.  Also  loosen  three 
screws  down  the  back  of  the 
side panel.