√ Combustion Blower failure - The Combustion Blower is not turning fast enough to generate the proper 
vacuum in the fire box. Visual Check – is the blower motor turning? 
√  Check  Vacuum  levels  in  the  exhaust  channel  by  bypassing  the  Vacuum  Switch,  then  remove  the 
Vacuum hose from Vacuum Switch.  Check exhaust vacuum readings by placing the open end of the 
Vacuum Hose on a Magnahelic Gauge (readings must be above 0.10” W.C. on low fire).  
  Note: If the motor fails to reach a 0.10” W.C. reading, then replace the Combustion Blower.
√  Poor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning 
or operational.
√  Exhaust Temperature Sensor failure – Bypass sensor located on Exhaust Blower. If stove now operates 
properly, the unit may require cleaning or a new sensor.  Contact your local dealer for service.
√  The unit may require cleaning.  Contact your local dealer for service.
√ Unplug the stove, open the left side panel. Jump the two (2) brown leads that are attached to the 
120°F (49°C) temperature sensor.  If the stove operates replace the 120°F (49°C) sensor.
3. The exhaust motor will not function normally
√ Open the left side panel, check all connections against the “W
IRING
 D
IAGRAM
” in this manual.
√ Thoroughly check for broken wires or connections.
√ If all the connections are verified and the exhaust blower does not function at all, tap lightly on the 
exhaust blower’s motor end cap. This may loosen a tight motor.
√ Apply 115 V AC directly to the exhaust blower.  If the motor does not run, replace the blower.
√ If the motor runs, check the exhaust potentiometer in the dial-a-fire. Remove the grey wires from 
the exhaust motor speed controller and measure the resistance (10Ω. to 400kΩ). If this range is not 
present or it is an open circuit, replace the speed controller. 
√ Check all wires for continuity.
√ Replace the exhaust motor phase control (speed control module).
√  Contact your local dealer for service.
4. The convection blower will not function normally
√  Check  all  the  connections  between  the  controller,  switch,  and  the  convection  blower  against  the 
“W
IRING
 D
IAGRAM
” in this manual.
√  If the convection motor will not run, apply 115 V AC to the motor directly.  If the motor runs, replace 
the fan controller.  If the motor does not run, the convection blower has failed.  Replace the blower.
√  If  the  convection  blower  runs  on  high  at  all  times  (no  control  with  the  fan  controller),  check  the 
connections  from  the  160°F  (71°C)  sensor  (located  on  the  upper  left  side  of  the  fire  wall)  and 
convection fan controller to the blower.  Disconnect one of the wires from the sensor. If control of the 
convection blower returns to the fan controller, replace the sensor.
√  If the motor is still on high, re-connect the sensor and replace the convection fan controller.
Troubleshooting
27