Heath Zenith 2LBL6 ユーザーズマニュアル

ページ / 4
Model 2LBL5: 150 Watt High Pressure Sodium Security Light
Model 2LBL6: 100 Watt Metal Halide Security Light
598-1318-01
NOTE: All wiring must be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or 
another acceptable means. Contact a qualifi ed electrician if there is any question as to the suitability of the system.
1.  Select a location on a fl at wall with structurally sound wood and 
from 10 to 25 feet from the ground. The wood should be at least 
one inch thick to safely secure the fi xture.
2.  Attach the cover plate using two large machine screws.
3.  Using the mounting bracket as a template. Hold it at the desired 
mounting location (making sure the bottom is level), and mark 
four mounting holes. We suggest drilling 3/16" pilot holes for the 
lag screws.
4.  Put the two top lag screws through their holes in the mounting 
bracket and hold them in place while you push the gasket onto 
these lag screws. Start these two screws into the two top pilot 
holes.
5.  Start the other two lag screws, and then tighten all four screws.
6.  Hang the fi xture on the mounting bracket using the slot in the 
cover plate.
7.  Twist the fi xture wires to the supply wires. (black to blackwhite 
to  white, and the bare fi xture wire to the supply ground 
wire
).
8.  Make sure the wires do not get pinched, and swing the fi xture up 
so the base fi ts tightly against the gasket. Push the pin through 
the hole at the top near the gasket, and into the mating loop in 
the mounting bracket. You may need to tap the pin to seat it all 
the way down.
9.  Secure the fi xture with the small machine screw going through 
the cover plate and into the mounting bracket.
10. Install lamp. Lamp rating must match the rating of the fi xture.
 
Model 2LBL5: 150 Watt high pressure sodium type S55 lamp.
 
Model 2LBL6: 100 Watt metal halide type M90/O open rated 
lamp.
11. Hold the lens and wire cage up to the fi xture and align the clips 
on the wire cage with the protrusions in the housing. Hook the 
clips over these protrusions and snap the clips closed to hold 
the lens and wire cage in place.
12. Loosen the screw in the center of the photocontrol socket two 
turns. Twist the socket so that the arrow points north. Note: There 
is a stop to prevent the socket from turning all the way around. 
If you have trouble turning the socket, try turning it the other 
direction. Retighten the screw in the center of the socket.
13. Align the photocontrol (it will only plug-in one way). Plug it in and 
twist clockwise until it stops.
14. Caulk fi xture mounting surface with silicone weather sealant
To test operation during daylight, cover the photocontrol with a 
small box. Turn on the power. Not all photocontrols are alike. Some 
may have a time delay of a few minutes, others will turn on as soon 
as power is applied. The light will take up to ten minutes to reach 
full brightness. Uncover the photocontrol and your unit will operate 
automatically—on at dusk, off at dawn.
Lag Screw 
(4)
Mounting
Bracket
Photocontrol
Gasket
Cover 
Plate
Lens
Pin
Lamp
Housing
 WARNING: Turn power off at the fuse or circuit 
breaker.
HEA 013
Printed in China
02/08
  Operating Instructions & Parts Manual 
2LBL5, 2LBL6
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain 
the product described. Protect yourself and others by observing all safety information. Failure to comply could result 
in personal injury and/or property damage! Save these instructions for future reference.
®
LPG-9272, LPG-9274
Lamp in Fixture Contains Mercury. Dispose According 
to Local, State, or Federal Laws.