Cooper Lighting TC プリント

ページ / 2
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
04/30/2007 8:47:23 AM
Specifications and Dimensions subject to change without notice.
ADC041425
PHOTOMETRICS
ORDERING INFORMATION
ORDERING MATRIX
11" ROUND
TC/TW
0
o
30
o
60
o
90
o
Zone        Lumens          %Lamp        %Fixture
0-  30
136
7.6
15.9
0-  40
245
13.6
28.6
0-  60
535
29.7
62.7
0-  90
839
46.6
98.2
0-180
854
47.5
100.0
0
1
2
3
4
5
6
7
8
9
10
CTTC-PP-26A-120
(1) PL-T/26W/30/4P Lamp
1800 Lumens 
Efficiency: 47.5%
Spacing Criterion: 1.7  
Ballast Factor:  1.0
Report # 767200
Zonal Lumen Summary
56  56  56  56      55  55  55  55       52  52  52          50  50  50           48  48  48            47    
50  48  45  43      49  46  44  42       42  42  41          42  41  39           40  39  38            37
45  41  37  34      44  40  36  33       38  35  32          36  33  31           34  32  30            29
41  35  30  27      39  34  30  26       32  29  26          31  28  25           29  27  25            24
37  30  26  22      36  30  25  22       28  25  22          27  24  21           26  23  21            20
33  27  22  18      32  26  22  18       25  21  18          24  20  18           23  20  17            16
30  23  19  15      29  23  18  15       22  18  15          21  17  15           20  17  14            13
28  21  16  13      27  20  16  13       19  15  12          18  15  12           18  15  12            11
26  18  14  11      25  18  14  11       17  13  11          17  13  11           16  13  10              9
24  17  12  9      23  16  12    9       16  12    9          15  12    9           14  11    9              8
22  15  11    8      21  15  11    8       14  10    8          14  10    8           13  10    8              7
Angle
0.0
0
151
5
152
10
153
15
157
20
161
25
165
30
169
35
173
40
175
45
177
50
176
55
171
60
163
65
148
70
127
75
101
80
71
85
46
90
27
Candlepower
Coefficients of Utilization
Effective floor cavity reflectance           20%
rc               80%                       70%                 50%                   30%                   10%                0%
rw      70  50  30  10     70  50  30  10       50  30  10           50  30  10           50 30  10             0
RCR
Notes: 
For additional options, consult your Cooper Lighting Representative. Specifications and dimensions subject to change without notice.
Products also available in non-US voltages and 50Hz for international markets.
1. Supplied from factory with deep casting. 2. Only available in HPF. 3. RP option not required when casting in supplied. 
*-Does not apply when using electronic ballast.