Cooper Lighting Microgem ユーザーズマニュアル
99
MICROGEM - RECESSED HOUSINGS
M
ICROGEM
ICROGEM
- RECESSED HOUSINGS
SHALLOW REMODEL HOUSING - ELECTRONIC
Item #
C800
Shallow Remodel - Elec. Xfmr. - 35W max.
Voltage
120
120V (Standard)
277
277V
• Housing adjusts 1.5” vertically to accommodate various ceiling
thicknesses.
• Integral electronic transformer accessible through the ceiling
opening.
• Transformers have thermal protection and operate at 11.5 volts
nominal.
• Primary leads: 120 volts.
• Transformer rated 180º Class H.
• Socket is pre-wired to the j-box with 18AWG SF-1 leads.
• Access above ceiling not required.
SHALLOW REMODEL HOUSING - REMOTE
Item #
SH2A
Shallow Remodel - for Remote power supply 35W max.
• Housing adjusts 1.5” vertically to accommodate various ceiling
thicknesses.
• Socket is 18AWG SF-1 leads.
THIS HOUSING IS NOT U.L. LISTED. CONTRACTOR MUST
FOLLOW N.E.C. CODE FOR CLASS 2 WIRING.
See page 101, 160-162 for remote transformers.
OVER ALL WIDTH (including mounting clips): 5.25”, ABOVE CEILING CLEARANCE: 3.00”
CEILING CUT-OUT: 3.75”
2.375"
3.63"
3.50"
10.63”
OVER ALL WIDTH (including mounting clips): 5.25”, ABOVE CEILING CLEARANCE: 3.00”
CEILING CUT-OUT: 3.75”
3.63"
3.50"