Cooper Lighting PLT26 プリント
Catalog #
Type
Project
COMBOLIGHT® COMBO CLASSIC RECESSED
LAMP GROUP 1 - CONFIGURATION “F”
TWO (2) Halogen lamp cells - ONE (1) Fluorescent lamp cells
New Construction Recessed Housing - Trim or Trimless
TWO (2) Halogen lamp cells - ONE (1) Fluorescent lamp cells
New Construction Recessed Housing - Trim or Trimless
ORDERING EXAMPLE:
= Two MR16 50W lamps with One BIAX® 40W Fluorescent • Double Wide • • Black Interior • White Trim • 120 volts
CR11650
F
BX40
BK
WH
120
Fluorescent >> BX40
BX50
PLL80 PLT26
PLT32
PLT42
T528
T535
T5HO39 T5HO54
Lamp Group 1
A
34.19” 34.19” 34.19” 16.69” 17.19” 18.19” 57.69” 69.69”
45.69”
57.69”
B
45.99” 45.99” 45.99” 24.49” 28.99” 35.29” 69.49” 81.49”
57.49”
69.49”
C
25.50” 25.50” 25.50”
8.00”
8.50”
9.50”
49.00” 61.00”
37.00”
49.00”
RSA
LIGHTING
®
RSA LIGHTING LLC 9660 - 9700 TOPANGA CANYON BLVD. CHATSWORTH CA. 91311
TOLL FREE: 800-356-3030 • 818-349-3030 • FAX: 818-349-3031 • www.rsalighting.com
©2003 RSA Lighting LLC All Rights Reserved • Specifications subject to change without notice.
SPECIFY -
F
380º x 45º locking
angular adjustment
45º visual cut-off
angular adjustment
45º visual cut-off
Fluorescent lamp cell
w/ integral ballast accessible
from below
w/ integral ballast accessible
from below
Integral reflector
Butterfly
Brackets
for Black Iron
Mounting
Brackets
for Black Iron
Mounting
Thermal Protector
Electronic
Low Voltage
Transformers
Low Voltage
Transformers
0.75" Trim
4.20"
4.30"
6.88"
6.00"
4.20"
B
A
C
Ceiling compund
is applied right
to the edge of the
fixture opening
is applied right
to the edge of the
fixture opening
TRIMLESS D
ET
A
IL
TR
IM
DETAIL
Must specify a diffuser or louver
for fluorescent cell. See below.
Ballast
Optional Accessories - See RSA Combo Classic accessory page for details.
Baffle
Snoots
Louvers
Lenses
Fluorescent Diffusers and Louvers - Please specify
❑ TWD - Textured White Diffuser
❑ CB1 - 2” Parabolic Louver
❑ MPD - Conical Prism Diffuser
❑ CB2 - 1” Parabolic Louver
Custom configurations are available with Combo Classic fixtures.
Also available with T8 fluorescent lamps. Consult RSA for details
DESCRIPTION:
An adjustable recessed fixture
suitable for multiple downlighting
applications with one point of elec-
trical entry. Mixes the use of low
voltage halogen lamps with fluo-
rescent lamps. Powder coat finish
on housing & lamp assembly.
An adjustable recessed fixture
suitable for multiple downlighting
applications with one point of elec-
trical entry. Mixes the use of low
voltage halogen lamps with fluo-
rescent lamps. Powder coat finish
on housing & lamp assembly.
CONSTRUCTION:
Housing, Plaster Frame & Trim
Assembly: 18 gauge CRS. J-Box
Assembly: 16 gauge CRS (galva-
nized). Fixture is offered with a .75”
ceiling trim or as a trimless fixture.
Can accommodate 0.50” to 1.00”
ceiling thickness.
Housing, Plaster Frame & Trim
Assembly: 18 gauge CRS. J-Box
Assembly: 16 gauge CRS (galva-
nized). Fixture is offered with a .75”
ceiling trim or as a trimless fixture.
Can accommodate 0.50” to 1.00”
ceiling thickness.
LAMP ASSEMBLY:
Four low voltage halogen lamp
cells with one fluorescent lamp
cell. Can accept up to two optical
accessories. 380º x 45º locking
lamp adjustment. Provides 45º
visual cut-off.
Four low voltage halogen lamp
cells with one fluorescent lamp
cell. Can accept up to two optical
accessories. 380º x 45º locking
lamp adjustment. Provides 45º
visual cut-off.
SYSTEM PROTECTION:
Thermal protection provided to
guard against overheating, and
misuse of insulation over and
around fixture. Vent holes in hous-
ing provide cooler operation
Thermal protection provided to
guard against overheating, and
misuse of insulation over and
around fixture. Vent holes in hous-
ing provide cooler operation
ELECTRICAL:
Fixture is two circuit.
Circuit 1: Integral electronic trans-
former for low voltage lamps.
Fused and short circuit protection.
Dimmable.
Fixture is two circuit.
Circuit 1: Integral electronic trans-
former for low voltage lamps.
Fused and short circuit protection.
Dimmable.
Circuit 2: Integral electronic bal-
lasts for fluorescent lamps.
Lutron® dimming ballasts avail-
able upon request.
lasts for fluorescent lamps.
Lutron® dimming ballasts avail-
able upon request.
Junction box is UL listed for
through branch wiring, for 8 #12,
90°C supply conductors or 60°C for
end of run (access above ceiling
not required).
through branch wiring, for 8 #12,
90°C supply conductors or 60°C for
end of run (access above ceiling
not required).
Made in the USA
.
Item # / Lamp Type
Configuration
Fluorescent Lamp Cell
Interior Finish
Trim Finish
Voltage
Lamp
Group 1
Group 1
CR11650 - MR16 12V 50W
F - Two Low Voltage Halogen
lamp cells with One
Fluorescent lamp cell
Fluorescent lamp cell
BX40 - 40W BIAX®
BK - Black
BK - Black
120 - 120 Volts
CR11675 - MR16 12V 75W
BX50 - 50W BIAX®
WH - White
WH - White
277 - 277 Volts
CR17020 - AR70 12V 20W
PLL80 - 80W PL-L
S - Silver
S - Silver
CR17050 - AR70 12V 50W
PLT26 - 26W PL-T
PT - Custom
PT - Custom
PLT32 - 32W PL-T
TR - Trimless
PLT42 - 42W PL-T
T528 - 28W T5
T535 - 35W T5
T5HO39 - 39W T5HO
T5HO54 - 54W T5HO
T528 - 28W T5
T535 - 35W T5
T5HO39 - 39W T5HO
T5HO54 - 54W T5HO
T8 lamps also available
___
___
___
___
___