Ei206D DataSht RevB
 
 
 
Model 
Ei206D 
Technical Specification 
 
1.  The CO Alarm carries the BSI Kitemark to indicate type testing to BS EN 50291:2001.  It is CE marked to indicate 
conformance to BS EN 60065: 1994, BS EN 50081-1: 1992 and BS EN 50270: 1992 Safety and Electromagnetic 
Compatibility Directives. 
 
2.  New generation electrochemical cell type Carbon Monoxide sensor checks CO concentration every 50 seconds. Each unit is 
calibrated and tested in CO gas in order to ensure accuracy. Sensor module plugs into base of unit and should be replaced 
after  5  years.  The  amber  „Fault‟ light  will  flash  once  every  40  seconds (without  a  beep)  to  indicate  the  sensor should be 
replaced. Replacement sensor modules, Ei261MEN, are readily available at modest cost. Does not require an electrician to 
change the sensor. 
 
3.
 
High  level  of  selectivity.  No  false  alarms  when  exposed  to  the  following  interference  gases  for  2  hours:  (as  per 
UL2034sec.38)  Methane  500ppm,  Butane  300ppm,  Heptane  500ppm,  Ethyl  Acetate  200ppm,  Isopropyl  Alcohol  200ppm 
and Carbon Dioxide 1000ppm. 
 
4.
 
Digital display will indicate the level of CO sensed when the unit is in alarm in parts-per-million (ppm). 
 
5.
 
Alarm  response  time  varies  with  CO  level  sensed:  at  50ppm  CO  sounder  operates  within  60-90  mins;  at  100ppm  CO 
sounder operates within 10-40 mins; at 350ppm CO sounder operates within 3 minutes. 
 
6.
 
Battery powered - supplied with 9V Alkaline PP3 battery. The green LED on the cover will flash every 50 seconds to indicate 
battery  power is  present.  The  alarm  will  emit  a  single  beep  every  50  seconds  (with  the  green  LED  flash)  to indicate  the 
battery needs replacement. 
 
7.
 
On first power up the green, red and amber LED‟s flash once; after 2 minutes settling, the unit operates normally. 
 
8.
 
Fault indicator - amber LED flashes and horn beeps every 50 seconds if a fault is detected. If sensor fault, digital display will 
show „SF‟. 
 
9.
 
Supplied with separate base-plate and fixing screws: suitable for ceiling or wall mounting. 
 
10.
 
Tamper resistant cover, which cannot be removed from mounting plate without releasing catch with a small screwdriver. An 
optional locking screw can be screwed into the side to prevent removal. 
 
11.
 
Manual  test/hush  button  -  test  button  to  test  circuitry  and  horn.  Pressing  and  releasing  the  test  button  when  the  unit  is 
sensing CO will silence the alarm for 4 minutes.  It will only silence once until the gas clears.  At 300ppm CO the unit cannot 
be silenced due to the increased danger. 
 
12.
 
Quick CO gas test - allows quick and easy testing of the unit with CO gas.  Pressing the test button causes the sensor to 
test for CO every 4 seconds.  The unit automatically resets after approximately 3 minutes. 
 
13.
 
Memory feature - pressing test button shows if CO has been detected during a period of absence: the unit will alarm and the 
digital display will show the level of CO previously sensed. Pressing the test button for 20 seconds resets the memory. 
 
14.
 
Built in sounder to give a minimum output of 85dB(A) at 3 metres. Modulated sound output - 3 rapid pulses followed by a 1½ 
second pause, repeated until reset. This easily differentiates it from a typical smoke alarm. 
 
15.
 
Automatic reset facility of alarm test when button is released, and after an alarm state when CO gas clears. 
 
16.
 
Operating temperature range: -5°C to +40°C (23°F - 104°F),  15% to 95% relative humidity. 
 
17.
 
Dimensions: 126mm x 150mm x 42mm.  Weight: 290g. 
 
18.
 
5 year guarantee 