Model 
Ei 100S Ionisation 
 
High sensitivity 
– responds to all standard fires 
 
Dual Ionization chamber - quick response to fast 
flaming fires 
 
Battery powered 
– 9V  (supplied) 
 
Needs no wiring 
 
Missing battery indicator 
 
Low battery warning 
 
Built in sounder  
 
Test and hush button 
 
Kitemarked to BS EN 14604:2005 
 
5 year guarantee 
 
 
Product Description 
 
The Ei100S is an Ionisation Smoke Alarm that runs on a 
9V  battery (supplied with the alarm).  
 
Ionisation smoke alarms operate on the principle that 
electrical current flowing between electrodes in an 
ionization chamber is reduced when smoke particles 
enter. 
 
Ionisation technology gives a rapid response to fast 
flaming fires, 
 
The Ei100S is easily installed and comes supplied with 
all necessary screw fixings. 
 
The Ei100S is fitted with a warning flag that pops up 
when the battery is removed. This prevents the cover 
from closing when there is no battery fitted to the unit. 
When the battery is being installed or changed, this flag 
must be held down while gently pushing the battery into 
the battery holder. 
 
When the battery is first connected, the alarm may sound 
for 2-3 seconds 
– 
this is normal and means that the 
battery is connected correctly
 
 
Operation
 
 
 
The smoke detector will activate the built in sounder 
upon sensing smoke particles 
 
 
Hush button to silence the unit for 10 minutes in 
case of nuisance alarm 
 
 
The smoke detector will automatically reset itself 
and silence the sounder when smoke particles are 
no longer present in the sensing chamber 
 
 
The built in sounder will provide a minimum sound 
output of 85dB at 3m 
 
 
The smoke detector has a built in warning flag to 
prevent installation of the detector without a battery 
fitted 
 
 
The “Test” button will perform a self test and sound 
the horn (it may take up to 10 seconds) 
 
 
The smoke detector will emit a beep every 40 
seconds to indicate that the battery back up is 
depleted and needs replacing 
 
 
9V BATTERY POWERED