Ei Electronics Ei154TL プリント

ページ / 1
230V AC SMOKE & HEAT ALARMS
AT
RECHARGEABLE LIT
CELL BACKUP
If you are also the installer see separate
“Siting & Installation Instructions”
USER INSTRUCTIONS
KEEP FOR REFERENCE
READ THIS FIRST
IMPORTANT USER INFORMATION
REGULARLY CHECK  THAT THE  GREEN  MAINS
INDICATOR LIGHT IS ON.
IF A NUISANCE ALARM OCCURS, FAN THE ALARM
VIGOROUSLY WITH  A NEWSPAPER  TO  HELP
CLEAR  THE  SENSOR. 
(ON  THE  EI151TL /  150  PRESS
THE HUSH BUTTON IN THE CORNER OF THE COVER)
.
TEST WEEKLY - PRESS THE BUTTON FOR 10 SEC-
ONDS AND A RED LIGHT BEHIND THE BUTTON OR
ON THE COVER SHOULD FLASH. INTERCONNECT-
ED ALARMS WILL ALSO SOUND.
CLEAN  YOUR  SMOKE  ALARM  REGULARLY.  THIS
WILL REDUCE THE RISK OF FALSE ALARMS.
REMOVE  OR  COMPLETELY COVER YOUR  SMOKE
ALARM  WHEN  REDECORATING  TO  PREVENT
DUST OR  OTHER  CONTAMINATION  DAMAGING
THE UNIT.
DO NOT ALLOW PAINT, WATER OR DUST TO CON-
TAMINATE YOUR ALARM.
YOUR  ALARM  IS  A MAINS  230V  AC  ELECTRICAL
APPLIANCE.  DO  NOT REMOVE  THE  COVER  OR
INSERT ANYTHING INTO THE ALARM.
DO  NOT PAINT YOUR  SMOKE  ALARM  -  IT MAY
ALARM OR CEASE TO OPERATE.
IF  YOUR  ALARM  SOUNDS  FOR  NO  REASON  AND
WILL NOT RESET,  IT CAN  BE  REMOVED  BY
RELEASING THE CLIP ON THE BASE. SWITCH OFF
MAINS FIRST.  
(SEE FIGURE 1, BELOW)
.
IF  BEEPING  OCCURS,  CHECK  THAT THE  GREEN
MAINS  LIGHT IS  ON.  PRESS  THE  TEST BUTTON
FOR 10  SECONDS.
The rechargeable
ay require a few days to charge
after first being c
to the mains.It may give a short
beep  every  40  seconds  for  up  to  2  hours  while  it  is
charging.
CHECKING & MAINTAINING YOUR ALARMS
INSPECTION & TESTING PROCEDURE
After installation, then at least weekly, check all your Alarms.
Also check after re-occupation following a holiday etc.
(i) Check that the green mains indicator light is on. (If it is off
check  circuit  breakers,  fuses  and  wiring  etc.)  Check  the  red
light behind the button or on the cover flashes every 40 sec-
onds.
(ii)  Press  the  test  button  (see
figure 2) for up to 10 seconds to
ensure  the  sensor  chamber,
electronics  and  sounder  are
working.  A red  light  behind  the
test  button  or  on  the  cover,  will
flash  while  horn  is  sounding.
The  alarm  will  stop  when  the
button is released. Pressing the
test  button  simulates  the  effect
of  smoke  or  heat    during  a  real  fire  and  is  the  best  way  to
ensure the Alarm is operating correctly.
WARNING: DO NOT TEST WITH FLAME.
This can set fire to the Alarm and damage the house.
We  do  not  recommend  testing  with  smoke  or  heat  as  the
results can be misleading unless special apparatus is used.
(iii) Check for any sign of contamination such as cobwebs or
dust and clean the alarm as described below if necessary.
Interconnected Alarms
Test the first unit by pressing the button for 10 seconds. All the
detectors should alarm within about 5 seconds of the first horn
sounding and the red light on the first unit only will flash about
once a second. Check all the other units similarly.
Checking Rechargeable Cells
(Models Ei 151TL, Ei 154TL & Ei 156TL only)
1. When the alarm is beeping
The Alarm automatically monitors the cells every 40 seconds
to ensure they are satisfactory. If  a problem is identified it will
give a short beep every 40 seconds. If the unit is giving beeps
then check the following:
(i) Check that the green mains power light is on. If it is off the
Alarm  has  been  powered  from  the  cells  and  the  beeps  indi-
cate they are depleted. Re-connect the mains, check fuse, cir-
cuit breakers and wiring. If in doubt contact a qualified electri-
cian.  The  beeps    should  cease  within  2  hours  as  the  cells
charge up.
(ii) Check that the hush button has not been pressed inadver-
tently (Ei 151TL only). This also causes beeps every 40 sec-
onds  for  up  to  15  minutes.  Press  the  test  button  to  cancel
hush mode beeps.
(iii) The cells may be depleted. The beeps should cease with-
in 2 hours as they charge up. Fully charged, the cells will pro-
vide up to 6 months back-up without mains power.
(iv) On the Optical Smoke Alarms only (Ei 155 & Ei 156TL)
if the unit beeps and the red light does not flash at the same
time  it  indicates  a  problem  with  the  smoke  chamber  -  see
Cleaning the Smoke Alarm.
If all of the above possible causes of beeps have been ruled
out but the beeping has still persisted for over 2 hours with the
green light on - the rechargeable cells are probably defective.
The  Smoke Alarm  must  be  returned  to  the  manufacturer  for
repair  or  replacement  (see  section  Getting  Your  Alarm
Serviced).
2. Manual Testing
2.  We  recommend  that  the  functioning  of  the  rechargeable
cells  (applicable  to  models  Ei  151TL,  Ei  154TL &  Ei  156TL
only) is checked periodically (at least yearly) as follows:
(i)  Ensure  that  the  alarm  has  been  connected  to  the  mains,
green light on, for a least 2 days for the cells to charge.
(ii)  Turn  off  the  mains  power  at  the  distribution  board  and
check  that  the  green  indicator  light  is  extinguished.  Do  not
remove the plug from the rear as this will disconnect the cells.
(iii) Press the test button and ensure the horn sounds loudly
for 10 seconds.
(iv)  Release  the  test  button  and  watch  it  carefully  for  one
minute:
• The red light behind the test button or on the cover will
flash at least once.
• The unit must not give a beep which indicates the battery
is low.
(v) Turn on the mains supply at the distribution board only if
the unit passes all the above tests.
Note: If the mains is disconnected and the battery is almost
depleted  the  unit  will  beep  every  40  seconds  for  at  least  72
hours. This is to remind you to re-connect the mains supply.
The unit will operate from the mains alone, even with a fully
depleted  or  a  defective  battery,  though  it  may  not  give  suffi-
cient  warning  of  fire  if  the  mains  supply  is  disconnected  for
any reason.
If there are any problems get a qualified electrician to inspect
the house wiring and connections to the alarms. If there are
still problems the unit must be returned for examination (see
section on Getting Your Alarm Serviced).
CLEANING YOUR ALARM
WARNING: Electrical shock hazard. Disconnect the AC mains
at the fuse box or circuit breaker powering the Alarm before
following the cleaning instructions.
Clean your Alarm regularly,particularly in dusty areas. Use the
narrow nozzle attachment of your vacuum cleaner to remove
dust,  insects  and  cobwebs  from  the  sides  and  cover  slots
where the smoke or heat enters. To clean the cover, wipe with
a damp cloth. Dry cover thoroughly with a lint free cloth. If the
contamination around the outer case indicates that the area is
particularly dirty, remove the Alarm from the ceiling (see figure
1
2
3
4
Electron cs
Electronics
IONISATION
T
MODELS
Ei151TL
& Ei150 
(WITHOUT
BACKUP CELLS)
OPTICAL
MODELS
Ei156TL
& Ei155
(WITHOUT
BACKUP CELLS)
HEAT
T
MODELS
Ei154TL
& Ei153
(WITHOUT
BACKUP CELLS)
SLIDE
OFF
Mounting
Plate
Tamperproof
Catch
Sealing
Gasket
Figure 1
Figure 2
1).  Check  that  the  openings  in  the  black  smoke  sensing
chamber are not clogged by visually inspecting them through
the large openings around the edges of the Smoke Alarms. If
they are clogged - an extremely rare occurance - the Smoke
Alarm must be replaced.
WARNING: Do not paint your Alarm.
Other than the cleaning described above, no other customer
servicing of this product is required.  Repairs, when needed,
must be performed by the manufacturer.
All  Alarms  are  prone  to  dust  and  insect  ingress  which  can
cause false alarms or failure to alarm.
The  latest  design,  materials  and  manufacturing  techniques  have  been
used in the construction of our Alarms to minimize the effects of contami-
nation. However it is impossible to completely eliminate the effect of dust
and insect contamination, and therefore, to prolong the life of the Alarm you
must ensure that it is kept clean so that excess dust does not build up. Any
insects or cobwebs in the vicinity of the Alarm should be promptly removed.
In  certain  circumstances  even  with  regular  cleaning,  contamination  can
build up in the smoke sensing chamber causing the alarm to sound or fail.
If this happens the alarm must be returned to us for servicing or replace-
ment. Contamination is beyond our control, it is totally unpredictable and is
considered  normal  wear  and  tear.  For  this  reason,  contamination  is  not
covered by the guarantee and a charge is made for servicing such units.
If  you  experience  persistent  false  alarms,  in  particular  loca-
tions, due to contamination of the smoke chamber you  could
consider  replacing  Optical  Smoke  Alarms  (Ei  156TL,  155)
with  Ionisation  Smoke  Alarms  (Ei  151TL,  150).    Ionisation
type  alarms  are  less  susceptible  to  dust  than  Optical  type
alarms.
NUISANCE ALARMS
Alarms caused by cooking fumes etc. can be readily silenced
by  fanning  the  unit  with  a  newspaper  or  similar.  On  the
Ei151TL, 150 units, simply press the hush button.
If, when the alarm goes off, there is no sign of smoke, heat or
noise to indicate that there is a fire, you should get your fam-
ily into a safe place, before you start investigating.
Check the house carefully in case there is a small fire smoul-
dering somewhere.
Check whether there is some source of smoke or fumes, for
example  cooking  fumes  being  drawn  past  the  Smoke Alarm
by an extractor.
If there are frequent nuisance/false alarms it may be neces-
sary  to  re-locate  the  device  away  from  the  source  of  the
fumes.
If  for  some  reason  the  alarm  continues  to  sound  without
smoke or heat being present (due to insect infestation or con-
tamination build-up for example) the Ei 150, 153 & 155 mod-
els can be silenced by disconnecting the mains power. In the
case of the Ei 151TL, 154TL & 156TL models (with recharge-
able cells) switching off the mains power alone will not silence
the alarm as it will still be powered by the cells. Switch off the
mains, remove the plug from the rear to disconnect the cells
(after  removing  the Alarm  from  the  ceiling  -  see  figure  1).  If
cleaning the Smoke Alarm does not correct the problem it can
be  returned  to  the  manufacturer  for  repair  or  replacement.
(see below).
Hush Feature
The Smoke Alarms (Ei 150 & 151TL only) have a Hush Button
to help you control nuisance false alarms.
1. To cancel a false alarm, press the Hush Button located on
the  lower  right-  hand  corner.  The  Alarm  will  automatically
switch to a reduced sensitivity condition (very large levels of
smoke from a nearby fire will override the Hush). This condi-
tion  allows  unwanted  alarms  to  be  silenced  for  a  period  of
approximately  10  minutes.  The  unit  will  give  a  short  beep
every 40 seconds during this time to let you know the unit
has been silenced.
On interconnected Smoke Alarms, pressing the Hush Button
on the one sensing smoke (i.e. the one with the red light flash-
ing  every  second)  will  silence  all  alarms.  Pressing  the  Hush
Button on any other Smoke Alarm will not cancel the alarm.
2.  The  unit  will  reset  to  normal  sensitivity  at  the  end  of  the
silenced period. If additional silenced time is required, simply
push the Hush Button again.
3. To quickly return to normal non-silenced operation, simply
push the Test Button ; the alarm will sound briefly and return
to its normal sensitivity alarm mode.
4.  After  installation,  your  Smoke  Alarm  may  beep  approxi-
mately every 40 seconds for 15 minutes. This indicates it is in
the  Hush  mode. To  put  it  into  normal  operating  mode,  push
and hold the Test Button until the alarm sounds.
IMPORTANT SAFEGUARDS
When  using  household  protective  devices,  basic  safety  pre-
cautions  should  always  be  followed,  including  those  listed
below:
Please read all instructions.
Rehearse emergency escape plans so everyone at home knows what
to  do  in  case  the  alarm  sounds.  Further  information  can  be  obtained
from  the  Home  Office  Publication  entitled  “Smoke  Detectors  in  the
Home” (FB2) or from your local fire prevention officer.
NOTE:  Constant  exposure  to  high  or  freezing  temperatures  or  high
humidity may reduce the life of the rechargeable cells.
To maintain sensitivity to smoke, do not paint or cover smoke alarm in
any  manner;  do  not  permit  any  accumulation  of  cobwebs,  dust  or
grease.
If unit has been damaged in any way or does not function properly,do
not attempt a repair. Return Alarm (see - Getting your Alarm Serviced).
This appliance is only intended for premises having a residential type
environment.
Smoke / Heat Alarms are not a substitute for insurance. The supplier or
manufacturer is not your insurer.
The chamber inside the Ionisation (Ei 151TL, 150) Smoke Alarm con-
tains  a  small  amount  of  radioactive  material.  Do  not  tamper  with  the
chamber. You may safely install and clean the Smoke Alarm following
this leaflet’s instructions.
Do not dispose of your Alarm in a fire.
Ionisation Smoke Alarms can be disposed of in normal household rub-
bish, no more than one alarm per dustbin.
PLANNING YOUR ESCAPE ROUTE FOR
WHEN THE ALARM GOES OFF
Use the Smoke / Heat Alarm Test Buttons to familiarize your
family with the Alarm sound and to practice fire drills regular-
ly with all family members. Draw up a floor plan that will show
each member at least 2 escape routes from each room in the
house.  Children  tend  to  hide  when  they  don’t  know  what  to
do. Teach children how to escape, open windows, and use roll
up fire ladders and stools without adult help. Make sure they
know what to do if the alarm goes off - see below.
1.  Check  room  doors  for  heat  or
smoke.    Do  not  open  a  hot  door.
Use  an  alternate  escape  route.
Close  doors  behind  you  as  you
leave.
2. If smoke is heavy, crawl out, stay-
ing  close  to  floor.  Take  short
breaths,  if  possible,  through  a  wet
cloth or hold your breath. More peo-
ple  die  from  smoke  inhalation  than
from flames.
3.  Get  out  as  fast  as  you  can.  Do
not  stop  for  packing.  Have  a  pre-
arranged meeting place outside for
all  family  members.  Check  every-
body is there.
4.  Call  the  Fire  Brigade  from  a
neighbour’s  house.  Remember  to
give your name and address.
5. NEVER re-enter a burning house.
Limitations of Smoke Alarms
Smoke Alarms have significantly helped to reduce the number
of fire fatalities in countries where they are widely installed.
However  independent  authorities  have  stated  that  they  may
be ineffective in some circumstances. There are a number of
reasons for this: 
The Alarms will not work if the mains power is off and in the
case  of  the  Ei  151TL,  154TL and  156TL if  the  cells  are
depleted.
Smoke / Heat Alarms will not detect fire if sufficient smoke
/ heat does not reach the alarm.  Smoke / heat may be pre-
vented from reaching the Alarm if the fire is too far away,
for example, if the fire is on another floor, behind a closed
door, in a chimney, in a wall cavity, or if the prevailing air
draughts carry the smoke away.  Installing Smoke / Heat
Alarms on both sides of  closed doors and installing more
than  one  Smoke  /  Heat  Alarm  as  recommended  in  this
leaflet  very  significantly  improves  the  probability  of  early
detection.
The Alarm may not be heard.
A Smoke  /  Heat Alarm  may  not  wake  a  person  who  has
taken drugs or alcohol.
Smoke / Heat Alarms may not detect every type of fire to
give sufficient early warning. They are particularly ineffec-
tive  with:  fires  caused  by  smoking  in  bed,  escaping  gas,
violent explosions. poor storage of flammable rags and/or
liquids,  (for  example  petrol,  paint,  spirits  etc),  overloaded
electrical circuits, arson and children playing with matches.
Smoke / Heat Alarms don’t last indefinitely. For example if
there  is  build  up  of  contamination  performance  will  be
impaired, and in the case of the EI 151TL, 154TL or 156TL
the rechargeable cells may eventually become too weak to
function correctly in the event of a mains power failure.
5
6
7
8
The manufacturer recommends replacement of the Smoke /
Heat Alarms after 10 years as a precaution.
GETTING YOUR ALARM SERVICED
If your Smoke Alarm fails to work after you have carefully read
all  the  instructions,  checked  the  unit  has  been  installed  cor-
rectly,  and  is  receiving  AC  power  (green  light  on)  contact
Customer Assistance at the address given at the end of this
leaflet. If it needs to be returned for repair or replacement put
it in a padded box and send it to “Customer Assistance and
Information”  at  the  nearest  address  given  on  the  Smoke
Alarm or in this leaflet. State the nature of the fault, where the
Smoke Alarm was purchased and the date of purchase. 
FIVE YEAR PRODUCT GUARANTEE
Ei Co. Ltd. guarantees this Smoke Alarm for five years from date of
purchase  against  any  defects  that  are  due  to  faulty  materials  or
workmanship. This guarantee only applies to normal conditions of
use and service, and does not include damage resulting from acci-
dent,  neglect,  misuse,  unauthorised  dismantling,  or  contamination
howsoever caused. This guarantee excludes incidental and conse-
quential damage. If this Alarm should become defective within the
guarantee period, it must be returned to the Ei Co, with proof of pur-
chase,  carefully  packaged,  with  the  problem  clearly  stated.  (see
“Getting Your Alarm Serviced”) We shall at our discretion repair or
replace the faulty unit.
Do not interfere with the Smoke Alarm or attempt to tamper with it.
This will invalidate the guarantee, but more importantly may expose
the user to shock or fire hazards.
This guarantee is in addition to your statutory rights as a consumer.
Ei Electronics,
Shannon, Co. Clare,
Ireland.
AICO Ltd.,
Oswestry,
Shropshire SY10 8NN
Phone: + 44 (0) 870 758 4000
Fax: + 44 (0) 870 758 4011
E-mail: enquiries@aico.co.uk
www.aico.co.uk
TROUBLESHOOTING
ALARM SOUNDS FOR NO APPARENT REASON:
(1) Identify the alarm source. On interconnected units the red
light under the test button or on the cover will flash rapid-
ly only on the unit which is the source of the alarm.
(2) Check for fumes, steam etc. from the kitchen or bathroom.
Paint and other fumes can cause nuisance alarms.
(3)  Fan  the  unit  vigourously  with  a  newspaper  to  disperse
fumes.
(4) If alarm does not stop, switch off mains and remove unit
(see figure 1). (only remove alarm with red light flashing,
the others are probably satisfactory)
ALARMS BEEPS CONTINUOUSLY:
(1) Alarms may be in ‘hush mode’. Press the test button for 10
seconds to reset the unit (Ei 151TL only).
(2) Cells may be flat due to mains failure (Ei 151TL, 154TL,
156TL only).  Check  the  green  mains  light  is  on.  If  not,
check fuse,circuit breakers and wiring connections.
(3)  If  the  above  fails  to  turn  on  the  green  light,  a  fault  may
exist. Switch off mains and remove the unit (see figure 1).
(4) If the green mains light is on and the action in (1) above
has not silenced the beeping, a fault may exist. Switch off
mains and remove the unit (see figure 1).
INTERCONNECTED ALARMS DO NOT ALL SOUND:
(1) Hold test button for 10 seconds after first alarm has sound-
ed to ensure signal is transmitted to all units.
(2) Switch off mains and check that live, neutral and intercon-
nect  cables  have  been  correctly  connected  and  that  the
connections are tight.
IF FREQUENT NUISANCE ALARMS OCCUR:
(1) Close kitchen / bathroom door when in use.
(2)  Ensure  that  the  alarm  is  sited  at  least  6m  away  from
sources of fumes.
(3)  Contamination  from  insects,  paint  or  paint  fumes  may
have occured. Clean the alarm.
(4) If the problem persists, re-siting of the unit should be con-
sidered. Alternatively, replace the unit with an Optical unit,
assuming  that  the  problem  is  with  an  Ionisation  type
alarm.
© Ei Electronics Ltd 2002
P/N 12930-3
9
10
11
12