Canon GC-251 ユーザーズマニュアル

ページ / 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
7
2.2. Controller 
(GC-251) 
Performance and shape 
 GC-251 
Number of control axes 
Control sampling 
100 kHz 
Maximum drive current 
10 A (each axis) 
Interface 
High-speed serial communication for position input (XY2-100) 
Control RS-232C 
Notch filter 
Digital notch filter    ×2 
Digital low-pass filter    ×1 
Analog notch filter    ×3 
Weight 500 
 
Environmental conditions 
Operating temperature and humidity 
0 to 50ºC, 90% RH or less (No condensation) 
Storage temperature and humidity 
-20 to 60ºC, 90% RH or less (No condensation) 
Note: The above operating temperature and humidity conditions depend on the operating and heat 
radiation conditions. 
 
Section names 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Heat radiation 
frame 
Mounting screw 
hole (M3 × 4) 
Digital board (upper) 
Analog board (lower) 
IF board 
Mounting screw 