Command Control
Serial Communication Configuration
Visit our website for additional RS-232 settings and information.
To control this projector via RS-232, connect a null modem cable and set the 
control system serial port settings to match the following communication 
configuration: 
RS-232 Port Settings
Setting
Value
Bits per second
19,200 
Data bits
Parity
None 
Stop bits
Flow control
None 
Emulation
VT100 
Network Communication Configuration
For network control, you can access the projector through Port 23 (Telnet).
We use the same control codes on serial as we do over the network. InFocus 
network control uses the Telnet packet structure.
Command Format
All commands consist of 3 alpha characters followed by a request, all 
enclosed in parentheses. The request can be a read request (indicated by a 
"?") or a write request (indicated by 1 to 4 ASCII digits).
A read request example: 
(AAA?) where
(starts the command
AAA denotes the command
? denotes the read request
) ends the command
Read Command Examples
Function
Command
Response 
Brightness
(BRT?)
(96-160,128)
Volume
(VOL?)
(0-32,16) 
Lamp Hours
(LMP?)
(0-32766, 42) 
A read command returns the range and the current setting, for example:
A write request example: 
(AAA####) where
(starts the command
AAA denotes the command
#### denotes the value to be written 
(leading zeros not necessary)
) ends the command
Some commands have ranges, while others are absolute. If a number 
greater than the maximum range is received, it is automatically set to the 
maximum number for that function. If a command is received that is not 
understood, a "?" is returned. With absolute settings, "0" is off, 1-9999 is on. 
The one exception is the Power command, where 0 is off and 1 is on.
To assure the projector can process a command, wait 3 seconds before enter-
ing the next command.